LUCE - ELLE - ARCO
20
• Remove the frame/front panel from the stove (see dedicated chapter).
• Connect with a tube to the digital pressure switch to detect depression (see
Fig. 46
).
• Load the feed screw via appropriate function.
• Start the stove and set "Set flame" to power 1 (the start-up time of this stove lasts between 8 and 10 minutes to ensure mini-
mum draught).
• Compare the read values with those on the table.
• Change power every 10 minutes and wait for it to stabilise.
• Access the user menu and, if necessary, change the parameters.
Fig. 46 - Digital pressure switch connection
DATA
P1
P2
P3
P4
P5
Stove depression - temperature
7 kW
25 Pa - 142°C
27 Pa - 172°C
34 Pa - 200°C
35 Pa - 217°C
36 Pa - 237°C
Stove depression - temperature
8,5 kW
25 Pa - 142°C
27 Pa - 172°C
34 Pa - 200°C
36 Pa - 225°C
43 Pa - 248°C
NB: for good combustion, the depression values must be between ± 5 Pa and the temperature values between ± 10°C.
7
SPECIAL MAINTENANCE
7.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an authorized
technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have your fume pipe, chim-
ney flue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical
elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked
more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
7.2
FUME CHAMBER CLEANING
Every end-of-season (or every 2000 hours of operation) it is necessary to clean the fume chamber.
• Open the door and release the panel below the door (see dedicated chapter).
• Remove the burning pot (see
Fig. 47
) from its seat and empty all ash.