34
11.4.4. EXTERNAL TEMPERATURE PROBE
It is possible to connect an external temperature probe on the Mini-Caddy. This temperature probe is used primarily to
reduce electricity consumption and reduce the bill by prioritizing the transition to an auxiliary heating source when it is
too cold outside or when it is the overcharging billing period (peak usage) depending on the electricity supplier.
HEAT PUMP :
With a combination wood, electrical element and heat pump you can set your temperature probe to not
use your heat pump when it is too cold and the coefficient of performance becomes too low. (Electrical element should
be prioritize during the configuration of the outdoor temperature probe.)
When the temperature probe is functioning, the « ECO » mode will show on the main page.
11.5. DISTRIBUTION BLOWER SPEED CONFIGURATION
It is possible to adjust the speed of the distribution blower for circulation mode, air conditioning and any other mode of
auxiliary heaters.
NOTE:
When heating with wood, the distribution blower speeds are programmed in order to provide the best thermal
exchange and cannot be changed.
It is possible to adjust the blower speed in “CIRCULATION” mode at any time by going in the main menu under
“SETUP” and “BLOWER SPEED”.
The blower speed adjustments for auxiliary heating are available only if the option was activated. The selected speed
in this menu will be the speeds used in the "CIRC", "COOL" and "HEAT" mode.
The adjustment of all controls must be done by a qualified technician. The controls settings and the blower speed must
conform to the recommendations of the CMMTQ.
11.5.1. DISTRIBUTION FAN SPEEDS
Your furnace is equipped with a 4-speed blower. Using the central processing unit, we have created 6 functional
speeds. Refer to the following table
for the various speed configurations.
SPEED
CORRESPONDING DATA
CFM*
STATIC
PRESSURE
1
Blower speed #1 using 90V
650
0.2’’ W.C.
2
Blower speed #1 using 115V
725
0.2’’ W.C.
3
Blower speed #2 using 98V
775
0.2’’ W.C.
4
Blower speed #2 using 115V
850
0.2’’ W.C.
5
Blower speed #3 using 115V
1100
0.2’’ W.C.
6
Blower speed #4 using 115V
1400
0.2’’ W.C.
*These results were measured at exit of plenum during laboratory tests. Results may vary depending of the
configuration and installation.
Summary of Contents for PF01302
Page 8: ...8 6 2 COMBINED WOOD ELECTRIC ...
Page 45: ...45 15 GENERAL ELECTRICAL DIAGRAM ...
Page 46: ...46 16 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE ...
Page 47: ...47 17 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT ...
Page 49: ...49 18 4 AIR CONDITIONNING DAMPER 18 5 HUMIDIFIER 18 6 HEAT PUMP ...
Page 50: ...50 19 EXPLODED VIEW AND PART LIST ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 54: ...54 ...