background image

21

LOCATION 175: PROGRAMMING ZONES 1, AND/OR 2 FOR NORMALLY CLOSED OPERATION ONLY 

Location 175 is used to program zones 1 and/or 2 for normally closed operation only, eliminating the need for the end
of line resistors on these zones. When a zone is programmed for normally closed operation, a short on that zone will
not change the loop condition, and an open on that zone will produce a faulted condition. This feature will be ignored
by any Priority zone. To program a zone for normally closed only, refer to the chart on the following page, and
program the appropriate data in this location. 

ZONES TO PROGRAM FOR N/C OPERATION DATA T0 PROGRAM IN LOCATION 175

"1"

"2"

2 & 1 "3"

LOCATION 176: SPLIT REPORTING - PROGRAMMING TAMPER, DOWNLOAD COMPLETE, AND AUTOTEST
                       TO REPORT TO THE SECONDARY PHONE NUMBER 

The 8000 is capable sending certain reports to the secondary telephone number. This feature known as split reporting
can be used to send alarm reports to one number and supervisory reports to another number. When using split
reporting with the 8000, the primary telephone number always takes priority over the secondary telephone number.
The 8000 always sends zone and alarm reports to the primary telephone number. There are 7 reports that can be
programmed to report to the second telephone number. Location 176 is used to force up to three of these individual
reports to the second telephone number. To program tamper, download complete, or autotest to report to the
secondary telephone number, use the following chart and program the appropriate number in location 176. 

REPORTS TO SEND TO SECONDARY NUMBER DATA T0 PROGRAM IN LOCATION 176

 AUTOTEST "2"

 DOWNLOAD COMPLETE "4"

 DOWNLOAD COMPLETE ; AUTOTEST "6"

 TAMPER "8"

 TAMPER ; AUTOTEST A = "10"

 TAMPER ; DOWNLOAD COMPLETE C = "12"

 TAMPER ; DOWNLOAD COMPLETE ; AUTOTEST E = "14"

Summary of Contents for Ranger 8000

Page 1: ...HOW TO PROGRAM THE RANGER 8000 6 KEYPAD PROGRAMMING EXAMPLES 7 PROGRAMMING PHONE NUMBERS FORMATS 8 9 COMMUNICATOR FORMAT SELECTION GUIDE 9 OPTIONAL PROGRAMMING INSTRUCTIONS 10 22 AVAILABLE ZONE TYPES 11 PROGRAMMING THE AUXILIARY OUTPUTS 17 DOWNLOAD PROGRAMMING INSTRUCTIONS 23 PROGRAMMING WORKSHEETS 24 26 LOCAL TELEPHONE COMPANY INTERFACE INFO 28 SPECIFICATIONS WARRANTY 30 CADDX CONTROLS INC GLADEW...

Page 2: ...description of how the Ranger 8000 functions After installation of the security system complete the information on page 1 of the User s Manual and explain the system operation to all security system users Standard Parts List The Ranger 8000 is shipped with the parts listed below QUANTITY PARTS DESCRIPTION PART 1 MASTER CONTROL PANEL 8000 1 REMOTE KEYPAD 8601 1 16 5VAC 25VA TRANSFORMER T 1625 10 3 ...

Page 3: ...3 PARTS DIAGRAM ...

Page 4: ...4 TERMINAL DRAWING SPECIAL NOTES ...

Page 5: ...tt at 8 or 16 ohm or 30 40 watt at 4 8 or 16 ohms If siren driver disable is selected in location 132 output becomes voltage output 12VDC 1 Amp maximum load 16 17 Smoke detector power 12VDC 100 mA maximum For those jurisdictions which allow the Priority zone to be used with smoke detectors 18 19 Auxiliary power regulated 12VDC 500 mA maximum 20 Earth Ground connect to a cold water pipe or 6 to 10 ...

Page 6: ...dicating the data in that location to be 6 If no LED s are illuminated the location contains a 0 To advance from location 000 through 180 press the key To go to a specific location press the location number followed by the key The yellow LED s will then display the data in that location Data is changed by entering a number 0 to 15 followed by r data enter key Review the examples in figure 1 on pag...

Page 7: ...7 ...

Page 8: ...this location and Radionics 1800HZ 2300HZ Fast with Parity and Hex Capability requires a 9 in this location If you need another format choose from those listed on the format table located on page 13 and program the data in location 052 If this location contains a 0 the built in communicator will be disabled and the Ranger 8000 will function as a local only control LOCATION 053 DISABLING THE SECOND...

Page 9: ...HZ HANDSHAKE DOUBLE ROUND PARITY 20 PPS 5 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 2300HZ HANDSHAKE DOUBLE ROUND PARITY 20 PPS EXTENDED HEX CAPABILITY 6 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 1400HZ HANDSHAKE DOUBLE ROUND PARITY 20 PPS EXTENDED HEX CAPABILITY 7 EXTENDED RADIONICS FAST 1800HZ TRANSMIT 2300HZ HANDSHAKE DOUBLE ROUND PARITY 40 PPS EXTENDED HEX CAPABILITY 8 EXTENDED RADIONICS FAST 1800...

Page 10: ...IGITS With the Ranger 8000 disarmed the Go To Program access code can be used to enter the program mode To disable the Go To Program access code program a 15 in location 028 The factory default setting is 9 7 1 3 LOCATIONS 032 074 SEE PAGES 8 9 LOCATION 075 PROGRAMMING THE ENTRY DELAY TIME Location 075 contains the number of 10 second increments in the entry delay The entry delay can be programmed...

Page 11: ...d or disarmed An open will create a Trouble condition Keypad LED will be steady for FIRE and flashing for Trouble 9 SECONDARY DELAY A secondary delay zone works like an entry exit delay zone but has its own independent delay time see locations 178 179 NOTE WHEN PROGRAMMING THE FOLLOWING COMMUNICATOR CODES A 10 MUST BE PROGRAMMED IN ORDER TO REPORT A ZERO 0 LOCATION 084 085 RESERVED LOCATION 086 08...

Page 12: ... programmed in location 094 is sent as the ones digit The tens digit is programmed in location 095 LOCATION 096 097 PROGRAMMING TO REPORT DOWNLOADING COMPLETE Locations 096 097 contain the communicator report sent each time a download session has been completed The report will come in after a disconnect has been made from a downloading session Location 096 contains the standard communicator code a...

Page 13: ...n 109 LOCATION 110 111 PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 4 Locations 110 111 contain the communicator code to be reported each time zone 4 creates an alarm Location 110 contains the standard digit and location 111 contains the extended digit When using 4 2 format the number programmed in location 110 is sent as the ones digit The tens digit is programmed in location 111 LOCATION 112 113 P...

Page 14: ...l be reported If a restoral code is programmed and an extended format is selected the restorals will be reported by zone If a restoral code is programmed and an extended format is not selected a restoral code will be sent when all of the previously reported conditions have restored When using 4 2 format the number programmed in this location is sent as the first or tens digit The second or ones di...

Page 15: ...RIVER 1 AMP VOLTAGE OUTPUT The built in siren driver has a steady sound for Priority zone type and a yelp sound for Burglary and Panic Factory default is 0 enabling this feature If the built in siren driver is NOT to be used take the following procedure First remove the jumper marked voltage siren on the PC board Next program a 1 in location 132 Finally replace the jumper in the voltage position T...

Page 16: ... will shutdown after the amount of time programmed in location 077 has elapsed Programming in this location does not affect the burglary siren LOCATION 141 DOUBLE LINE EXTENDED ALARM REPORTING If an extended format is selected in location 052 and a 1 is programmed in location 141 all reports will be double line extended If location 141 contains a 0 only non alarm reports will be extended restore c...

Page 17: ...T 3 PRIORITY SIREN RECYCLED OUTPUT 4 ARMED WITH BYPASS LATCHED OUTPUT 5 AC POWER LATCHED OUTPUT 6 LOW BATTERY LATCHED OUTPUT 7 ALARM MEMORY LATCHED OUTPUT 8 ENTRY LATCHED OUTPUT 9 EXIT MOMENTARY OUTPUT LOCATIONS 149 INVERTING THE AUXILIARY OUTPUTS Auxiliary outputs are normally OFF and turn ON when the selected condition occurs For outputs you wish to reverse add up their values according to the c...

Page 18: ...4 this location should contain a 4 which is the ones digit of the current year If the current year is 1995 this location should contain a 5 which is the ones digit of the current year LOCATION 156 PROGRAMMING THE CLOCK CURRENT DAY OF THE MONTH TENS DIGIT Location 156 contains the current day of the month tens digit If the current day of the month is the 5th 05 this location should contain a 0 whic...

Page 19: ...it of the minutes after the hour that the autotest is desired The time is entered in 24 hour time If the desired autotest time is 5 25 PM the 24 hour time is 17 25 so this location should contain a 2 which is the tens digit of the minutes for autotest time If the desired autotest time is 9 36 AM the 24 hour time is 09 36 this location should contain a 3 LOCATION 165 PROGRAMMING THE AUTOTEST TIME M...

Page 20: ...time user number 7 arms the control The desired closing code should be programmed in this location This feature can be used in conjunction with the rotating maintenance code to give a closing report each time the maintenance code is used to arm When using an extended format the extended code will always be a 7 CAUTION If a Quick Arm code has been selected and the first digit of the rotating mainte...

Page 21: ...e 8000 is capable sending certain reports to the secondary telephone number This feature known as split reporting can be used to send alarm reports to one number and supervisory reports to another number When using split reporting with the 8000 the primary telephone number always takes priority over the secondary telephone number The 8000 always sends zone and alarm reports to the primary telephon...

Page 22: ...E 9 AC FAIL OPEN CLOSE A 10 AC FAIL OPEN CLOSE MAINT CODE OPEN CLOSE B 11 AC FAIL LOW BATTERY C 12 AC FAIL LOW BATTERY MAINT CODE OPEN CLOSE D 13 AC FAIL LOW BATTERY OPEN CLOSE E 14 AC FAIL LOW BATTERY OPEN CLOSE MAINT CODE OPEN CLOSE F 15 LOCATION 178 PROGRAMMING THE SECONDARY ENTRY DELAY ZONE TYPE 9 Location 178 contains the number of 10 second increments in the secondary entry delay This delay ...

Page 23: ...RNING CALLBACK PHONE NUMBER SHOULD ALWAYS BE REVIEWED FOR ACCURACY BEFORE DISCONNECTING LOCATION 210 ANSWERING MACHINE DEFEAT Location 210 contains the answering machine defeat enable To defeat an answering machine two telephone calls must be made to the premises On the first call let the phone ring the same number of times or less as the number programmed in location 210 maximum 3 The control pan...

Page 24: ...073 8 SECONDARY ACCOUNT CODE 0 DISABLED 074 9 SECONDARY FORMAT 0 DISABLED CONTROL COMMUNICATOR FEATURES LOCATION PAGE DESCRIPTION DATA DEFAULT 075 10 ENTRY DELAY TIME 10 SECOND INCREMENTS 3 30 SECONDS 076 10 EXIT DELAY TIME 10 SECOND INCREMENTS 6 60 SECONDS 077 10 SIREN SHUTDOWN RECYCLE TIME OUT 2 MINUTE INCREMENTS 4 8 MINUTES 078 11 ZONE 1 TYPE 3 ENTRY EXIT 079 11 ZONE 2 TYPE 5 INT FOLLOWER 080 1...

Page 25: ...1 15 AUTO BYPASS INSTANT ARMING 0 DISABLED 132 15 SIREN DRIVER OR VOLTAGE OUTPUT 0 SIREN DRIVER 133 15 LED EXTINGUISH FEATURE 0 DISABLED 134 15 NUMBER OF DIAL ATTEMPTS 8 EIGHT ATTEMPTS 135 15 POWER UP CONDITION 0 LAST CONDITION 136 15 POWER UP DELAY 0 60 SEC DELAY 137 15 IMMEDIATE RESTORE BY ZONE 0 DISABLED 138 16 NO ARMING WITH ZONE BYPASSED 0 DISABLED 139 16 QUICK ARM DIGIT 0 DISABLED 140 16 FIR...

Page 26: ...ING MAINTENANCE CODES SEED CODE DIGIT 4 0 172 20 USER 7 MAINTENANCE CODE OPENING REPORT 0 DISABLED 173 20 USER 7 MAINTENANCE CODE CLOSING REPORT 0 DISABLED 174 20 PROGRAM ZONES 3 THRU 6 FOR NORMALLY CLOSED OPERATION 0 SUPERVISED 175 21 PROGRAM ZONES 1 AND OR 2 FOR NORMALLY CLOSED OPERATION 0 SUPERVISED 176 21 SPLIT REPORT TAMPER DOWNLOAD COMPLETE AUTOTEST 0 PHONE 1 177 22 SPLIT REPORT AC FAILURE L...

Page 27: ...rrect the situation The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone company may make changes in its communications facilities equipment operations or procedures where such action is reasonably required and proper in its business Should any such change render the custome...

Page 28: ...FACTURING IF ANY DEFECT APPEARS DURING THE WARRANTY PERIOD RETURN IT TO CADDX POSTAGE PREPAID THE UNIT WILL BE REPAIRED AND RETURNED FOR THE REMAINING 36 MONTHS OF WARRANTY THE UNIT WILL BE REPAIRED FOR A FEE NOT TO EXCEED 10 00 PLUS SHIPPING AND HANDLING CADDX ASSUMES NO LIABILITY FOR CONSEQUENTIAL OR INDIRECT DAMAGE AND ACCEPTS NO RESPONSIBILITY FOR REPAIRING DAMAGE TO THE PRODUCT CAUSED BY MISU...

Reviews: