22
WARNING
Connections to the main power
and the electrical system must
comply with the regulations in force in
the country of installation of the
appliance; and all connections must be
performed by qualified personnel
authorized by UNOX. Failure to comply
with these regulations may cause
damage and injuries, invalidates the
warranty* and relieves UNOX of all
liabilities.
Before connecting the appliance
to the mains electricity, always compare
the power supply data with that of the
appliance specified on the rating plate.
The appliance is released from the
factory with power cable and plug already
connected to the terminal. Do not make
any other type of electrical connection
and no dimensional modification of the
cable other than extensions, replacing it
only with one having specifications
equal to the original factory cable (type
of rummer, cross-section, etc.).
The cable must be replaced by
CADCO or by its technical
assistance service, and in all cases by a person
with similar qualification in order to avoid
possible risks.
The wiring diagrams, wire
specifications and the technical
data are indicated on the
“Technical
specifications” sheet
attached to the
appliance.
For proper electrical connections, the
appliance must:
Be wired into an equipotential system in
accordance with current regulations. This
connection must be performed between
different appliances
with the terminal marked with the
equipotential symbol
. The cable must have a maximum
cross-section of 10 mm2 (pursuant
standard CEI EN 60335-2-42:2003-
09) and be of yellow-green color.
-
Must be grounded to the
earthing (green-yellow wire).
-
Must be connected to a thermal
differential switch in compliance
with the regulations in force (0.03A
Type A).
-
Must be connected to an omni polar
circuit breaker mechanism that
enables complete disconnection in
category III over voltage conditions.
CHECKS
-
The copper jumper in the terminal
board and the electrical cable must
be secured together under the
screw in its tightening direction; and
the electrical connections must be
securely tightened before connect-
ing the appliance to the electricity
mains.
-
Check for any electrical dispersion
between the phases and the
ground, and for electrical continuity
between the external casing and the
main ground line.
-
Check that the power supply volt-
age does not deviate from the
nominal voltage value specified on
the appliance rating plate when the
appliance is operating. If this is not
the case, wire the phases as
specified on the “technical specifi
-
cations” sheet attached.
Electrical Grounding Instructions: appliance is
equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
Summary of Contents for BAKERLUX SHOP.Pro XAKPT-08HS-C