background image

PLUMBING 

�  CONNECTIONS 

INCOMING WATER 

The  bottom  of  the  appliance 

contains  two  meters  of  pipe  with 

a  tee  for  connecting  to  the  oven 

water supply (including mechanical 

filter  and  fitting  (3/ 4")  with  non­

return valve). 

A shut-off valve should be positioned 

between  the  water  mains  and  the 

appliance. 

�  Use thesetofnewconnections 

'U' 

supplied  with  the  appliance 

for  the  connection  to  the 

water  mains.  Connections  that 

have  already  been  used  must  not 

be used again. 

I

WARNING! 

The  equipment 

must  be  Installed  with  adequate 

backflow  protection  to  comply 

with  applicable  federal,  state  and 

local codes. 

INLET WATER CHARACTERISTICS 

�  Any  damage caused by using 

'U' 

water with parameters that do 

not  correspond  to  what  is 

specified  in  this  section  is  not 

covered by the  warranty. 

The water supply must: 

- have  a  maximum  temperature  of

86 °F (30 °C);

- be drinkable;

- be  pressured  at  between 22  and  87

psi (150-600 kPa).

26 

�  If water pressure at the inlet is 

¥

less 

than 

the 

minimum

specified  value  (22  psi  - 1.50

bar)  a  pump  (minimum  water  flow 

rate 1.32  gpm (300  1/h)) is required. 

The  ovens  have  a  built-in  pressure 

reducer. 

If water conductivity is greater than 

150  µS/cm  a  water  treatment  for 

steam production is required. 

Damage  caused  by  limescale 

or  other  chemical  agents  is  not 

covered by the warranty

Summary of Contents for BAKERLUX SHOP.Pro XAKHT-HCFS

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...IDE REPAIR SHOULDBE DONEBY AUTHORIZED SERVICE PERSONNEL ONLY GENERAL SAFETY Read this guide carefully before installing or maintain ing the appliance and conserve this guide with care for any future c...

Page 5: ...als and cor rectly disposed of in compliance with local regulations The ratings plate provides essential technical infor mation that is of utmost importance for any appliance maintenance or repairs Do...

Page 6: ...and water supplies and contact a Cadco au thorized customer assistance service Do not attempt to independently repair the appliance R equest Cadco original spare parts for any repairs necessary To en...

Page 7: ...nvalidates the warranty PICTOGRAMS The installation and user instructions are valid for all models unless otherwise specified by the following pictograms Danger Situation presenting immediate danger o...

Page 8: ...t exit the oven when the door is opened Table A COOKING TRAYS tffi I We recommend you thoroughly read for all instructions on how to maintain the aesthetic and functionaI qualities of your purchased p...

Page 9: ......

Page 10: ......

Page 11: ...d from the factory and must only be transported using pallets supplied by Cadco Each unit has been carefully inspected before it was packaged and consigned to a shipper installer Upon delivery Inspect...

Page 12: ......

Page 13: ...using pallet jacks I WARNING The packaging material is potentially dangerous It must be kept out of the reach of children and animals and correctly disposed of in compliance with local regulations ST...

Page 14: ...fied technicians in compliance with local state and federal regulations CHECKING PACKAGE CONTENTS BeforeinstaIIingthe applianee check that the following components are in the package and undamaged Con...

Page 15: ......

Page 16: ...Top oven flue model STEFANIA ARIANNA Bottom oven flue model STEFANIA ARIANNA 16 ft Make sure that you do not mix up the smoke flue connections and the condensation outlet OUT...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...ust pipe on the top portion of the appliance Where multiple ovens are stacked the bottom oven and the one those above must be connected to the hood To do this you must use the extension included in th...

Page 21: ......

Page 22: ......

Page 23: ...here are no W objects or materials obstructing the flue or which maybedamaged by thetemperature or fumes Do not leave flammable materials near the smoke exhausts 2 Evacuation through an efficient vent...

Page 24: ...correct connection can lead to personal injury or even electrocution Incorrect connection of the W electrical wires may damage the appliance O grey or white neutral wire black red blue phase L1 L2 L3...

Page 25: ...s connection must be performed between different appliances with the terminal marked with the equipotential symbol if The cable must have a maxim crnss section of 10 mm2 pursuant standard CEI EN 60335...

Page 26: ...comply with applicable federal state and local codes INLET WATER CHARACTERISTICS Any damage caused by using U water with parameters that do not correspond to what is specified in this section is not...

Page 27: ...drops of reagent Cadco Finest Cl 10 ppm 2 drops of reagent Reverse Osmosi System NHM 500 S cm Reverse Osmosi System use the reagent in the Cadco KSTR1081A kit hardness measured using the Cadco KSTR108...

Page 28: ...filter UNOX Finest O cold water supply thermally controlled by a temperature sensor IN 28 lPO liiii JID Plumbing connection to the left Jfliilii i 11il Plumbing connection to the ri ht itlUiiiiil J P...

Page 29: ......

Page 30: ...ns and the conden sation outlet OUT Top oven ELENA Bottom oven out Top oven ROSSELLA 0 f residual water discharge OUT 30 A It is recommended that the hood use a floor drain to discard the spent water...

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...ggressive or corrosive deter gents e g hydrochloric muriatic or sulphuric acid abrasive or sharp tools abrasive sponges scrapers steel bristled brushes etc water jets EXTERNAL STEEL SURFACES Wait for...

Page 37: ......

Page 38: ......

Page 39: ...onnected to the hood _J Manufacturer s Information Cadco Ltd 200 International Way Winsted CT 06098 860 738 2500 lsmith cadco ltd com www cadco ltd com Possible cause ISolution The hood is not connect...

Page 40: ......

Reviews: