9. Maintenance

•   Check flexible tubing between regulator and heater regularly and replace if perished, worn or damaged. In any case replace tubing 

taking into consideration the expiration date

•   Refer any major maintenance to the agent named on last page of this manual.
•   It is recommended that the heater is serviced every two years by authorized personnel.

SYMPTOMS

FAULT

REMEDY

Pilot will not light automatically.

No spark across electrode gap.

a)  Ensure that piezo-electric switch is    
     functioning correctly
b)  Check electrical lead connections
c)  Check that electrical lead is not dam 
     aged
d)  Check that the spark plug is satisfactory
e)  Check that spark is passing to the  
     earth electrode or thermocouple but not  
     to the grid

Pilot will not light automatically but 
points (a) to (e) are satisfactory and 
the pilot will light with a match.

Incorrect position of spark in relation to pilot 
gas flow

Re-position spark plug so that spark jumps 
across gas flow.

Heater will not remain alight when 
pressure is released from ignition 
button.

Electro-magnetic valve closes whilst heater 
is alight

a)  Ensure that thermocouple probe is  
     located in pilot flame
b)  Ensure good connection between  
     thermocouple and valve
c)  Check thermocouple
d)  Check electromagnetic valve

After changing to maximum position 
with all three plaques alight, one or 
more plaques appear below normal 
intensively.

a)  Blocked jets
b)  Partially blocked supply tube

a)  Remove and clean blocked jet
b)  Remove supply tube, remove jet and  
     blow through the tube

Difficulty in crosslighting from  
position 1 to position 2 or 3.

a)  Air draught directed away from 1st  plaque 
b)  Position of the pilot flame

a)  Change the location of the appliance  
     so that it is not adversely affected by  
     air draught.
b)  Position pilot so that flame impinges  
     across bottom corner of 2nd plaque as  
     well as 1st plaque

Smell of combustion

Missing piece of ceramic fireclay

Inspect perimeter of each plaque and 
locate place where some fireclay has been 
displaced. Repair with PYRUMA and leave 
to set for approximately 24 hours.

8. Cleaning 

•   Use a damp cloth wrung out in a solution of soapy water to clean the exterior and cylinder storage area of your heater.
•   Make sure that no water gets onto the burners or pilot/light area. Wipe the heater completely dry before use.
•   Do not use abrasive cleaners as they may damage the quality of paint finish.

•  

Do not expose your cylinder to extreme heat.

•  

Do not locate any other cylinders within the space/room in which your heater is used.

•  

Do not insert your finger or any other material through the front panel of the heater.

•  

Leave at least 1 meter distance between your heater and the other heat source.

•  

Do not let unauthorized persons to interfere with your heater.

•  

Do not place appliance under socket outlet.

•  

Do not use the heater in surroundings of a bath, shower of swimming pool.

•  

This heater must not be used without a gas cylinder fitted for stability purposes.

•  

Do not cover your heater.

•  

Fabrics, clothing or other flammable materials may ignite if placed against the outlets of your heater.

•  

The guard on this appliance is to prevent risk of fire or injury from burns and no part of it should be permanently removed. IT DOES 

NOT GIVE FULL PROTECTION FOR YOUNG CHILDREN OR THE INFIRM.