1
1
CAUTION
Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
must be provided.
IMPORTANT
Read these instructions carefully so as to familiarise yourself with the appliance before fitting the appliance to a gas cylinder.
Retain these instructions for future reference.
GB
1. General
• This Appliance complies with EN 498:2012, EN 484:2019 and SANS 1539:2017.
• This appliance shall only be used with an approved hose and regulator.
• The gas cartridge/refillable cylinder is to be used only in the upright position.
• Note: To ensure satisfactory operation when using a cartridge always start up with a full cartridge and only when the intended period of
continuous operation is less than approximately 45 minutes.
• Gas appliances require ventilation for efficient performance and to ensure the safety of users and other persons in close proximity as the
appliance consumes oxygen.
• Use Outdoors Only
• Only to be used with a gas cylinder that does not exceed 500mm in height (regulator not included) and 400mm in width.
• When using a pot, the minimum recommended pot size is 150mm and maximum recommended size is 300mm.
5650
Country of use
DK, FI, NO, NL, SE, AT,
DE, SI
BE, ES, FR, IE, IT, PT,
GB, CH
PL
AT, DE
Appliance Catagories
I3B/P (30)
I3+ (28-30/37)
I3B/P (37)
I3B/P (50)
Allowable gases and
operating pressure
G30-Butane @
28-30 mbar
G31-Propane @
28-30 mbar
G30-Butane/
G31-Propane mixtures
@ 28-30 mbar
(S. Africa - LPG @
2,8kPa)
G30-Butane @
28-30 mbar
G31-Propane @ 37 mbar
G30-Butane @ 37 mbar
G31-Propane @ 37 mbar
G30-Butane/
G31-Propane mixtures
@ 37 mbar
G30-Butane @ 50 mbar
G31-Propane @ 50 mbar
G30-Butane/
G31-Propane mixtures
@ 50 mbar
Nominal usuage
Butane - 218 grams/hour
Butane - 218 grams/hour
Butane - 218 grams/hour
Butane - 218 grams/hour
Gross nom. heat input
3 kW
3 kW
3 kW
3 kW
Jet number
85
81
74
Gas supply sources:
a)
A refillable gas container not exceeding 11kg and complying with local regulation in force.
b)
CA 445/CA 500 Cadac or equivalent EN417 compliant disposable cartridge with CADAC Power Pak 500.
Country name abbreviations
AT=Austria
DK=Denmark
GB=UnitedKingdom
NO=Norway
BE=Belgium
ES=Spain
IE=Ireland
PL=Poland
CH=Switzerland
FI=Finland
IT=Italy
PT=Portugal
DE=Germany
FR=France
NL=Netherlands
SE=Sweden
SI=Slovenia
Summary of Contents for 5650
Page 2: ......
Page 6: ...4 4 GB A B C E F G D ...
Page 13: ...11 11 DE A B C E F G D ...
Page 20: ...18 18 NL A B C E F G D ...
Page 28: ...26 26 FR A B C E F G D ...
Page 35: ...33 33 DK A B C E F G D ...
Page 42: ...40 40 NO A B C E F G D ...
Page 49: ...47 47 IT A B C E F G D ...
Page 56: ...54 54 ES A B C E F G D ...
Page 63: ...61 61 PL A B C E F G D ...
Page 70: ...68 68 SE A B C E F G D ...
Page 77: ...75 75 SI A B C E F G D ...
Page 84: ...82 82 A B C E F G D FI ...