CAC / BDP KSACN0201AAA Owner'S Manual Download Page 7

7

TURBO SETTING

S

TURBO: The unit on the high fan speed generates quick
cooling or heating so the room temperature can quickly
approach the setting value.

In the COOLING or HEATING mode press FUNCTION until
the unit enters the TURBO mode then press ENTER/CANCEL to
confirm.

When the TURBO function is activated, press FUNCTION  to
enter the TURBO  mode and then press ENTER/CANCEL  to
cancel (see Fig. 15).

Fig. 15

 - 

Turbo mode

BLOW SETTING

S

BLOW Function: After the unit turns off, the water in
the indoor unit’s evaporator automatically evaporates to
avoid mildew.

In the COOLING or DRY modes, press FUNCTION until the unit
enters the BLOW mode and then press ENTER/CANCEL to
activate the function.

When the BLOW function is activated, press FUNCTION, under
the BLOW mode interface, then press ENTER/CANCEL to
cancel the function (see Fig. 16).

Fig. 16

 - 

Blow mode

NOTE:  

When BLOW is activated and the user turns off the unit by pressing ON/OFF or with the remote controller, the indoor fan will run
at low speed for 2 minutes, and “BLOW” appears on the LCD. If BLOW is deactivated, the indoor fan turns off. The BLOW
function is unavailable in the FAN or HEATING mode.

Summary of Contents for KSACN0201AAA

Page 1: ...tential for personal injury Understand these signal words DANGER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or produc...

Page 2: ...n for the outdoor unit 10 Gate control function Not available on these units 11 Lock function 12 SHIELD Shield functions Button operation temperature setting On Off operation Mode setting are disabled by the remote monitoring system 13 Turbo Turbo function state 14 MEMORY Memory function the indoor unit resumes the original setting condition following a power failure and power recovery 15 Blinks u...

Page 3: ...s under the unit s OFF state to ENTER CANCEL the memory function if the memory is set the indoor unit after a power failure and the power recovery will resume it s original setting state If not the indoor unit is default to OFF after a power recovery MEMORY OFF is the default before delivery 3 6 Press at the same time under the unit s OFF state appears on the wired controller for the cooling only ...

Page 4: ...Fan Heating Fig 7 MODE Setting TEMPERATURE SETTING Press or to increase or decrease the temperature If these buttons are pressed continuously the temperature either increases or decreases by 1 8_F 1_C every 0 5s see Fig 8 In the COOLING DRY FAN or HEATING mode the temperature setting range is 60 8_F 86_F 16_C 30_C In the AUTO mode the setting temperature can not be adjusted Fig 8 Temperature Mode ...

Page 5: ...iming value Next press ENTER CANCEL to confirm S CANCEL TIMER After setting the timer if TIMER is pressed LCD will not display xx HOUR so the timer setting is canceled Fig 11 displays the TIMER OFF setting under the unit s ON state Fig 12 Displays the TIMER ON setting under the unit s OFF state Fig 11 Timer off Setting under the unit s ON state Fig 12 Timer off Setting under the unit s OFF state T...

Page 6: ...five seconds later SLEEP MODE S SLEEP ON Press FUNCTION under the unit s ON state until the unit enters the SLEEP mode Press ENTER CANCEL to confirm S SLEEP OFF When the SLEEP function is activated press FUNCTION to enter the SLEEP mode Next press ENTER CANCEL to exit the function In the COOLING or DRY modes the temperature increases by 1 8_F 1_C after the unit runs under the SLEEP mode for 1 hour...

Page 7: ...f the water in the indoor unit s evaporator automatically evaporates to avoid mildew In the COOLING or DRY modes press FUNCTION until the unit enters the BLOW mode and then press ENTER CANCEL to activate the function When the BLOW function is activated press FUNCTION under the BLOW mode interface then press ENTER CANCEL to cancel the function see Fig 16 Fig 16 Blow mode NOTE When BLOW is activated...

Page 8: ...speed and LOCK function INSTALLATION AND DISASSEMBLY CONNECTION TO THE HIGH WALL INDOOR UNIT Consult the installation instructions of each indoor unit for proper installation Connect the 4 core wire shipped with the wired controller to the wire with a molex connector shipped with the unit and already connected to the PCB Board to COM INNER1 WIRED REMOTE CONTROLLER SIGNAL LINE CONNECTION S Open the...

Page 9: ...t panel and the wired remote controller plate tightly with the screws ST2 9X6 1 6 8 9 10 7 3 4 5 2 Fig 18 Installation Steps Please pay special attention to the following directions during the connection to avoid air conditioning malfunction due to electromagnetic interference CAUTION 1 Separate the wired remote controller signal and communication lines from the power cord and connection lines bet...

Page 10: ... error U1 Whole unit over current protection E5 Compressor demagnetization protection HE Over phase current protection P5 7 H g n i z i n o r h c n y s e d r o s s e r p m o C c H n o i t c e t o r p C F P IPM Temperature Protection P8 IPM Current protection H5 Over power protection L9 Compressor phase loss reversal protection Ld System charge shortage or blockage protection F0 Frequency restricte...

Reviews: