CAC / BDP KSACN0201AAA Owner'S Manual Download Page 3

3

WIRED REMOTE CONTROLLER BUTTONS

Enter/cancel

Enter/Cancel

Fan

Mode

Function

Timer

On/Off

1

4

5

6

7

8

2

3

Fig. 4

 - 

Wired Remote Controller Buttons

WIRED REMOTE CONTROLLER BUTTON FUNCTIONS

Table 2—Controller Button Functions

No.

Name

Function

1

Enter/Cancel

Function selection and cancellation

2

Running temp. setting of the indoor unit, range: 60.8

°

F~86

°

F (16

°

C~30

°

C)

Timer setting, range:0.5-24 hr.

6

3

Fan

Setting of the high/middle/low/auto fan speed

4

Mode

Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit

5

Function

Switchover among the functions of Turbo/Save/Blow etc..

7

Timer

Timer setting

8

On/Off

Turn on/off the indoor unit

4+2

Press together for 5s under the unit’s OFF state to ENTER/CANCEL the
memory function (if the memory is set the indoor unit, after a power failure and 
the power recovery, will resume it’s original setting state. If not, the indoor unit 
is default to OFF after a power recovery. MEMORY OFF is the default before
delivery).

3+6

Press at the same time under the unit’s OFF state,

appears on the

wired controller for the cooling only unit, while 

 appears on the wired 

controller for the cooling and heating unit.

2+6

Upon startup of the unit without malfunction or under the unit’s OFF state,
press them at the same time for 5s to enter the lock state, in which case, 
any other buttons will not respond. Repress them for 5s to quit the state. 

4+6

Mode

If there is a preference for 

°

F rather than 

°

C (default), under the OFF state, press

and hold MODE and decrease   temperature set point buttons together for 5
seconds. 

Summary of Contents for KSACN0201AAA

Page 1: ...tential for personal injury Understand these signal words DANGER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or produc...

Page 2: ...n for the outdoor unit 10 Gate control function Not available on these units 11 Lock function 12 SHIELD Shield functions Button operation temperature setting On Off operation Mode setting are disabled by the remote monitoring system 13 Turbo Turbo function state 14 MEMORY Memory function the indoor unit resumes the original setting condition following a power failure and power recovery 15 Blinks u...

Page 3: ...s under the unit s OFF state to ENTER CANCEL the memory function if the memory is set the indoor unit after a power failure and the power recovery will resume it s original setting state If not the indoor unit is default to OFF after a power recovery MEMORY OFF is the default before delivery 3 6 Press at the same time under the unit s OFF state appears on the wired controller for the cooling only ...

Page 4: ...Fan Heating Fig 7 MODE Setting TEMPERATURE SETTING Press or to increase or decrease the temperature If these buttons are pressed continuously the temperature either increases or decreases by 1 8_F 1_C every 0 5s see Fig 8 In the COOLING DRY FAN or HEATING mode the temperature setting range is 60 8_F 86_F 16_C 30_C In the AUTO mode the setting temperature can not be adjusted Fig 8 Temperature Mode ...

Page 5: ...iming value Next press ENTER CANCEL to confirm S CANCEL TIMER After setting the timer if TIMER is pressed LCD will not display xx HOUR so the timer setting is canceled Fig 11 displays the TIMER OFF setting under the unit s ON state Fig 12 Displays the TIMER ON setting under the unit s OFF state Fig 11 Timer off Setting under the unit s ON state Fig 12 Timer off Setting under the unit s OFF state T...

Page 6: ...five seconds later SLEEP MODE S SLEEP ON Press FUNCTION under the unit s ON state until the unit enters the SLEEP mode Press ENTER CANCEL to confirm S SLEEP OFF When the SLEEP function is activated press FUNCTION to enter the SLEEP mode Next press ENTER CANCEL to exit the function In the COOLING or DRY modes the temperature increases by 1 8_F 1_C after the unit runs under the SLEEP mode for 1 hour...

Page 7: ...f the water in the indoor unit s evaporator automatically evaporates to avoid mildew In the COOLING or DRY modes press FUNCTION until the unit enters the BLOW mode and then press ENTER CANCEL to activate the function When the BLOW function is activated press FUNCTION under the BLOW mode interface then press ENTER CANCEL to cancel the function see Fig 16 Fig 16 Blow mode NOTE When BLOW is activated...

Page 8: ...speed and LOCK function INSTALLATION AND DISASSEMBLY CONNECTION TO THE HIGH WALL INDOOR UNIT Consult the installation instructions of each indoor unit for proper installation Connect the 4 core wire shipped with the wired controller to the wire with a molex connector shipped with the unit and already connected to the PCB Board to COM INNER1 WIRED REMOTE CONTROLLER SIGNAL LINE CONNECTION S Open the...

Page 9: ...t panel and the wired remote controller plate tightly with the screws ST2 9X6 1 6 8 9 10 7 3 4 5 2 Fig 18 Installation Steps Please pay special attention to the following directions during the connection to avoid air conditioning malfunction due to electromagnetic interference CAUTION 1 Separate the wired remote controller signal and communication lines from the power cord and connection lines bet...

Page 10: ... error U1 Whole unit over current protection E5 Compressor demagnetization protection HE Over phase current protection P5 7 H g n i z i n o r h c n y s e d r o s s e r p m o C c H n o i t c e t o r p C F P IPM Temperature Protection P8 IPM Current protection H5 Over power protection L9 Compressor phase loss reversal protection Ld System charge shortage or blockage protection F0 Frequency restricte...

Reviews: