8. TROUBLESHOOTING 
 

a.  Ensure you are using quality multiple shielded cables with quality radial or 

compression F-connectors. 

 
b.  Ensure the F-connector’s center conductor is making solid contact with the 

CTA-30RK-550’s Input and Output ports, and the appropriate headend combiner and 
RF distribution network connectors. 

 

c.  When taking measurements it is always best to use a quality signal level meter.    

System level measurements should be taken from the CTA-30RK-550’s Output port.  
For field maintenance, the CTA-30RK-550’s Test port may be used.  However, note 
that port is padded down -30dB and the 30dB must be added back in when determining 
system level settings and output.   

 

d.

 

Further troubleshooting assistance can be found on-line at 

www.northamericancable.com

 and 

www.cabletronix.com

 in addition to support from 

Cabletronix sales engineers at 1-610-429-1511.

 

 

5

Summary of Contents for CTA-30RK-500

Page 1: ...INSTALLATION MANUAL CTA 30RK 550 Rack Mount Distribution Amplifier 1 ...

Page 2: ...le slope control adjustable gain control output test port and double shielded RFI enclosures SPECIFICATIONS CTA 30RK 550 Rack Mount Distribution Amplifier Specifications Typical RF 1 Bandwidth 54 550 MHz 2 Gain 30 dB 3 Gain Adjust Range 0 12 dB variable 4 Slope 0 9 dB variable 5 Flatness 0 5dB per channel 1 5dB any 100MHz band 6 Noise Figure 5 dB 7 Maximum Output 45 dB 8 Cross modulation 57 dB 9 S...

Page 3: ...NICAL INSPECTION Inspect the front and rear of the equipment for shipping damage Make sure the equipment is clean and no connectors are broken damaged or loose If equipment appears to be damaged or defective please contact us at 1 610 429 1511 for assistance 3 PRODUCT DIAGRAM c d e h g f i 1 Power Power On indicator light 2 Gain Adjust For RF gain adjustment 3 Tilt Adjust For Slope adjustment over...

Page 4: ...d below will product intermodulation and picture distortion Number Of Channels Maximum Level Input dB Maximum Level Output dB 7 44 66 12 41 53 36 32 54 54 16 46 Turn the CTA 30RK 550 s Gain Adjust control to achieve the input and output levels identified above Additional attenuators may be needed to achieve the above input and output levels The CTA 30RK 550 s Tilt Adjust control should be used to ...

Page 5: ...ng measurements it is always best to use a quality signal level meter System level measurements should be taken from the CTA 30RK 550 s Output port For field maintenance the CTA 30RK 550 s Test port may be used However note that port is padded down 30dB and the 30dB must be added back in when determining system level settings and output d Further troubleshooting assistance can be found on line at ...

Reviews: