CableTronix CTA-30RK-1000 Installation Manual Download Page 5

installed in this amplifier to compensate for this slope in cable resulting in a flat 
frequency response at the output

 

 
 
 

8. TROUBLESHOOTING 
 

a.  Ensure you are using quality multiple shielded cables with quality radial or 

compression F-connectors. 

 
b.  Ensure the F-connector’s center conductor is making solid contact with the 

CTA-30RK-1000’s In and Out ports, and the appropriate headend combiner and RF 
distribution network connectors. 

 

c.  When taking measurements it is always best to use a quality signal level meter.    

System level measurements should be taken from the CTA-30RK-1000’s Out port.  For 
field maintenance, the CTA-30RK-1000’s Test port may be used.  However, note that 
port is padded down -30dB and the 30dB must be added back in when determining 
system level settings and output.   

 

d.

 

Further troubleshooting assistance can be found on-line at 

www.northamericancable.com

 and 

www.cabletronix.com

 in addition to support from 

Cabletronix sales engineers at 1-610-429-1511.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 