installed in this amplifier to compensate for this slope in cable resulting in a flat
frequency response at the output
8. TROUBLESHOOTING
a. Ensure you are using quality multiple shielded cables with quality radial or
compression F-connectors.
b. Ensure the F-connector’s center conductor is making solid contact with the
CTA-30RK-1000’s In and Out ports, and the appropriate headend combiner and RF
distribution network connectors.
c. When taking measurements it is always best to use a quality signal level meter.
System level measurements should be taken from the CTA-30RK-1000’s Out port. For
field maintenance, the CTA-30RK-1000’s Test port may be used. However, note that
port is padded down -30dB and the 30dB must be added back in when determining
system level settings and output.
d.
Further troubleshooting assistance can be found on-line at
www.northamericancable.com
and
www.cabletronix.com
in addition to support from
Cabletronix sales engineers at 1-610-429-1511.