LANVIEW LED SIGNALS
Page 4-6
assignments take effect immediately at start-up, but are relevant
only if the module boots into default mode. In default mode,
although the LEDs will be YELLOW for FNB rings 2, 3, 4 and Aux
rings 1, 2, the rings will still be inaccessible.
In management mode, all ring speeds are set by the management
module.
4.2.6 IN USE - Ring In Use
This LED indicates the status of network communication on the
associated TRXMIM ring. It does not reflect ring activity that
excludes this TRXMIM (e.g. on rings bypassed from the TRXMIM).
If the LED is:
OFF,
no ports are inserted into the associated ring.
GREEN,
at least one port on the module is successfully inserted into
the associated ring.
BLINKING GREEN,
at least one port is inserted into the ring, but the ring itself is
bypassed from the FNB by management command.
Because Auxiliary rings are never attached to the FNB, their
IN USE LEDs do not go to BLINKING GREEN.
Because passive MAUs are inserted only when actually
passing data, they may cause the LED to appear to flash
intermittently rather than blink consistently.