Page 1: ...SWPIM BRI LNK STS Title Page SWPIM BRI Installation Guide 9033038 02 ...

Page 2: ......

Page 3: ...oned in this manual may be trademarks or registered trademarks of their respective companies FCC NOTICE This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been ...

Page 4: ...ified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal...

Page 5: ...nly the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the Program 3 APPLICABLE LAW This Lice...

Page 6: ...d computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 3...

Page 7: ... the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the Program 3 APPLI...

Page 8: ...d computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 3...

Page 9: ... LICENSE You have the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble th...

Page 10: ...ed computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 ...

Page 11: ...55022 EN 55024 EN 60950 EN 60825 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above directives Manufacturer Legal Representative in Europe Mr Thomas R Whissel Mr Jim Sims ___________________________________ _________...

Page 12: ...Notice x SWPIM BRI Installation Guide ...

Page 13: ...SWPIM BRI 1 1 1 2 Installing the SWPIM BRI 1 2 1 3 LANVIEW LED Indications 1 4 1 4 Connecting to the Network 1 5 1 5 Completing the Installation 1 5 APPENDIX A SPECIFICATIONS A 1 Physical Properties A 1 A 2 Network Interface A 2 A 2 1 Pinout for the S T Interface Connector A 2 A 2 2 Pinout for the U Interface Connector A 3 A 3 Environmental Requirements A 3 A 4 Regulatory Compliance A 4 APPENDIX B...

Page 14: ...Contents xii SWPIM BRI Installation Guide ...

Page 15: ...m designed to receive the SWPIM Sliding WAN Physical Interface Module architecture USING THIS GUIDE Read through this guide completely to understand the features and capabilities of the SWPIM BRI A general working knowledge of WAN and Ethernet and IEEE 802 3 data communications networks and their physical layer components is helpful before using the SWPIM BRI Only qualified personnel should perfor...

Page 16: ...etron Systems product that supports the SWPIM architecture such as the SSR 600 or the HSIM SSR 600 The SWPIM BRI uses a single RJ48 connector supporting the S T interface and the U interface There are two different pin assignments and cables for the two interfaces Refer to Appendix A for the Cabletron Systems part numbers and pin assignments for these cables The S T interface is provided via a fou...

Page 17: ...ld Wide Web in Adobe Acrobat Portable Document Format PDF at the following site http www cabletron com Cabletron Systems applicable software manuals for the SSR 600 and the HSIM SSR 600 host platforms Cabletron Routing Software Manuals Bridging Configuration Guide Event Logging System Message Guide Network Interface Operations Guide Routing Protocols Reference Guide Routing Protocols User s Guide ...

Page 18: ... attention to any item of information that may be of special importance TIP Tip symbol Conveys helpful hints concerning procedures or actions CAUTION Caution symbol Contains information essential to avoid damage to the equipment Electrical Hazard Warning symbol Warns against an action that could result in personal injury or death due to an electrical hazard ...

Page 19: ...stems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring problem etc Any previous Return Material Authorization RMA numbers World Wide Web http www cabletron com Phone 603 332 9400 Internet mail support cabletron com FTP ftp...

Page 20: ...Introduction xviii SWPIM BRI Installation Guide ...

Page 21: ...WPIM BRI 2 Attach the antistatic strap refer to the instructions in the wrist strap package before removing the SWPIM BRI from the antistatic packaging 3 Verify that the SWPIM BRI is undamaged Refer to Getting Help if there is any damage to the device Do not attempt to install the SWPIM BRI if it is damaged Only qualified personnel should install the SWPIM BRI CAUTION Failure to observe static saf...

Page 22: ...nd employed as recommended 4 Remove the SWPIM BRI from the antistatic bag Save this bag in the event the device must be removed from the host platform 5 Hold the SWPIM BRI with the faceplate facing away right side up from the host platform The 40 pin connector should be facing towards the empty slot with the wide part of the connector oriented down See Figure 1 1 6 Locate the rail guides inside th...

Page 23: ...The SWPIM BRI must be configured before the WAN connection is made Once the SWPIM BRI has been configured the host platform must undergo a soft or hard restart in order for the SWPIM BRI to be recognized and for traffic to pass Refer to the appropriate software manual to configure the SWPIM BRI CAUTION Do not connect any WAN cables until the SWPIM BRI has been configured in software The phone comp...

Page 24: ...LED indications for the SWPIM BRI Table 1 1 Link LED Color Indication Off Disabled or Not Configured Red No Link Blinking Red Failure Blinking Amber Transmit or Receive Traffic Green Port is Active Table 1 2 Status LED Color Indication Off Normal or Disabled Blinking Amber Port in Loopback Test Mode Green Active Call B1 and or B2 is Active Blinking Green Failure due to Framing Errors ...

Page 25: ...05 x where x is the length of the cable Figure 1 2 Typical Configurations 1 5 COMPLETING THE INSTALLATION After installing the SWPIM BRI the SWPIM BRI will need to be configured for the network Refer to the host platform software documentation in order to set up and manage the SWPIM BRI using the software SSR 600 SWPIM BRI S T interface Site 2 WAN Cloud NT SSR 600 SWPIM BRI U interface Site 1 U in...

Page 26: ...Chapter 1 Installation 1 6 SWPIM BRI Installation Guide ...

Page 27: ...Cabletron Systems reserves the right to change these specifications at any time without notice A 1 PHYSICAL PROPERTIES Dimensions 1 91 H x 5 40 W x 19 05 D cm 0 75 H x 2 125 W x 7 50 D in Weight Unit 90 7 g 3 2 oz Nominal current draw on 5V supply from host platform U interface 126 5 mA passing traffic S T interface 135 mA passing traffic MTBF Predicted 3 874 392 hours ...

Page 28: ... 9360005 x where x is the length of the cable A 2 1 Pinout for the S T Interface Connector The connector for the S T interface can be seen in Figure A 1 Figure A 1 S T Interface RJ48 Pinout Table A 1 Pinouts for the S T Interface Connection Pin Function Polarity Terminal Equipment TE Network Equipment NE 1 No Connection No Connection 2 No Connection No Connection 3 Transmit Receive 4 Receive Trans...

Page 29: ...for the U interface is shown in Figure A 2 Figure A 2 U Interface RJ48 Pinout A 3 ENVIRONMENTAL REQUIREMENTS Table A 2 Pinouts for the U Interface Connection Pin Signal Direction 1 No Connection 2 No Connection 3 Uline I O 4 Uline I O 5 No Connection 6 No Connection Operating Temperature 5 to 40 C 41 to 104 F Non operating Temperature 30 to 90 C 22 to 194 F Operating Humidity 5 to 90 Non condensin...

Page 30: ...following safety and electromagnetic compatibility EMC requirements Safety UL 1950 CSA C22 2 No 950 73 23 EEC EN 60950 IEC 950 EN 60825 Electromagnetic Compatibility EMC FCC Part 15 CSA C108 8 89 336 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 AS NZS 3548 VCCI V 3 Telecommunications FCC CFR47 Part 68 CS 03 ...

Page 31: ...ble If your equipment needs repair it should not be reconnected until it is repaired 4 If the telephone company finds that the equipment is exceeding tolerable parameters the telephone company can temporarily disconnect service although they will attempt to give you advance notice if possible 5 Under the FCC Rules no customer is authorized to repair this equipment This restriction applies regardle...

Page 32: ...ompany or an authorized agent It is the responsibility of the users requiring service to report the need for service to our Company or to one of our authorized agents Service can be obtained at Cabletron Systems Technical Support Address Cabletron Systems Inc 35 Industrial Way Rochester NH 03867 0505 Phone 603 332 9400 Internet mail support cabletron com ...

Page 33: ...onnected complies with Part 68 of the Commission s rules except for the encoded analog content and billing protection specifications With respect to encoded analog content and billing protection I attest that all operations associated with the establishment maintenance and adjustment of the digital CPE with respect to encoded analog content and encoded billing information continuously complies wit...

Page 34: ...uthorized representative using training materials and instructions provided by the manufacturer grantee of the equipment used to encode analog signals or c An independent training course e g trade school or technical institution recognized by the manufacturer grantee of the equipment used to encode analog signals or d In lieu of the proceeding training requirements the operator s maintainer s is a...