background image

1

2

3

STS-LM Stacker Link Module

Introduction

The SmartStack STS-LM Stacker Link Module is a single port 
interface module, used to stack switches, that is installed into 
the rear slot of the SmartStack Token Ring Switch. When two 
SmartStack switches are connected through two STS-LM 
modules, the switches can be combined to form one logical 
switch. The STS-LM front panel is shown in Figure 1.

Figure 1.  SmartStack STS-LM Front Panel

SmartStack STS-LM Package Contents

The STS-LM package contains the following items:

One STS-LM Stacker Link Module for the SmartStack 
Token Ring Switch

One Stacker Link cable

One SmartStack STS-LM Installation Guide (this 
document)

Installation

Use the following steps when installing the STS-LM module 
in the SmartStack switch.

Note: Stacker Link modules are not hot-swappable. Always 
be sure that the power is off before installing or removing a 
module. If the power is on, damage to the equipment may 
result. Once the module is installed in the CrossFire 8600 
Token-Ring Switch, external cables may be connected or 
removed without having to remove power from the switch.

1. Disconnect power to the switch.

2. If a blank cover is over the stacker slot on the back panel, 

remove it by unscrewing the two attachment screws.

3. To prevent possible static damage to the module, hold it by 

its edges only. Be careful not to touch the top or bottom.

4. Slide the module into the slot evenly, taking care to line up 

the edges with the guides.

5. Seat the module by pressing the front of the module with 

your thumbs.

6. Secure the module to the chassis by tightening the thumb 

(panel) screws at the left and right edges of the module’s 
front panel. Do not overtighten the screws.

7. Return power to the switch.

SmartStack STS-LM Connectors and LEDs

The following tables describe the connectors and LEDs on the 
STS-LM front panel.

Connecting the Stacker Link Cable

The proprietary 50-pin cable must be used to connect the
STS-LM in a stack.

The SmartStack switch can be configured in three different 
ways to form a stack of switches:

Two SmartStack switches via two STS-LM modules

Up to five SmartStack switches via four STS-LM modules and 
one STS-5SU Stacker Unit

Up to eight SmartStack switches via eight STS-LM modules 
and one STS-8SU Stacker Unit

When inserting the cable connector, keep the connector 
straight to minimize the risk of bent or damaged pins.

Working with a Stack

When the SmartStack switch powers up, it runs through a 
series of diagnostics. Immediately after the diagnostics are 
complete, the SmartStack switch enters the stack discovery 
mode. The discovery mode is used to sense if the unit is cabled 
to other SmartStack switch units. If the SmartStack switch is 
connected to other units during the discovery mode, the 
switches automatically combine to form a stack.

Each unit is assigned a box number. The switch with the lower 
MAC address becomes Box 1, the switch with the higher 
MAC address becomes Box 2 and so forth. When accessing 
switch specific settings from a management console, you will 
be prompted for a box number.

The switches in the stack combine certain configuration 
parameters so that the stack as a unit uses one set of 
parameters. These parameters are discussed below in “Inter-
box Parameters”.

The stack can now be managed as a single entity from a 
management console or management application.

Inter-box Parameters

The SmartStack switches participating in the stack must 
combine configuration information so that the stack as a whole 
uses common parameters. One of the participating switches 
becomes the provider of inter-box parameters.

If the switches have the same configuration information, the 
switch that becomes Box 1 becomes the provider. If the 
configuration information is different, a split-stack will be 
formed and a warning message will be displayed on the 
console screen. You will be requested to briefly press the 
SysReq button on the switch that is to be the provider of inter-
box parameters. When you have selected the provider, the 
other switch will replace its stack related configuration 
parameters with those of the provider.

Connector

Description

Stacker Port

50-pin SCSI-2 connector for proprietary 
Stacker Link cable.

Table 1.  STS-LM Network Connector

LED

State

Description

TX

On

Data is being transmitted to the 
attached switch.

RX

On

Data is being received from the 
attached switch.

ATTACH Off

No connection has been established.

On

A connection has been established.

Table 2.  STS-LM LEDs

Reviews: