Initiating MMAC-Plus Remote Management
2-3
Getting Started
Figure 2-2. Sample Chassis Setup Window
-
Click on the Module Type drop down list box, and drag to select the
appropriate module type for the device installed in the corresponding
slot (currently the 9E132 and 9E133 series Ethernet MicroLAN
Module, 9F120 series FDDI Concentrator Module, 9F116 series
FDDI Bridge/Router Module, and 9T-122 series Token Ring MicroLAN
Module. Bridge and FDDI support is also available for the 9A128
series ATM Module; although this module has not been documented,
its current functionality is identical to the 9F116 module. Other
modules are not yet supported via Remote Management).
Note that when you select a module, its community name field will
automatically default to public.
-
In the IP Address field, type in the network address assigned
to the client module installed in the corresponding slot. Make
sure the address is in valid dotted decimal notation format (i.e.,
XXX.XXX.XXX.XXX, where XXX ranges from 1 to 254).
-
The Community Name field will be used in future releases of MMAC-
Plus Remote management. The SNMP Community Name acts as
both the local and remote password with which you can manage the
device. For information on setting your client module’s community