APPENDIX B: IMAGE FILE DOWNLOAD USING OIDs
B-4
SEHI USER’S GUIDE
When performing the steps in table 1, keep the following in mind:
•
You must follow the steps in order.
•
Enter the IP address of the tftp server in standard dotted decimal
notation (e.g., 132.177.118.24).
•
Enter the FULL path to the image file in the ctDLTFTPRequest
OID, including the name of the image file
(e.g., c:\tftpboot\sehi.hex).
Table B-1. OIDs and Settings
Step
OID Name
OID Number
Data
Type
SNMP OID
Data
1.
ctDLForceOnBoot
1.3.6.1.4.1.52.4.1.5.8.1.1.0
integer
1
2.
ctDLCommitRAMToFlash
1.3.6.1.4.1.52.4.1.5.8.1.2.0
integer
1
3.
ctDLTFTPRequestHost
1.3.6.1.4.1.52.4.1.5.8.1.4.0
IP
address
Enter the IP
address of
the tftp
server.
4.
ctDLTFTPRequest
1.3.6.1.4.1.52.4.1.5.8.1.5.0
string
(ASCII)
Enter the
path to the
image file.
5.
ctDLInitiateColdBoot
1.3.6.1.4.1.52.4.1.5.8.1.3.0
integer
1