Setting the Mode Switches
MicroMMAC Installation Guide
Page 3-5
•
Switch 6 - Forced Download. Changing the state of this switch (i.e.,
moving the switch from one position to another) clears download
information from NVRAM and forces the MicroMMAC to download
an image file from the station acting as the BOOTP/TFTP server of the
MicroMMAC.
After changing the state of this switch, and repowering the device, the
MicroMMAC requests a new image until it either receives a new
image, or you reset the MicroMMAC again by using the Reset button
on the front panel.
Reset the MicroMMAC a second time. The device attempts to locate
a BOOTP server again. However, the BOOTP request times out after
about one minute, and the MicroMMAC boots from FLASH memory.
•
Switch 7 - Cabletron Systems use only.
•
Switch 8 - Password Defaults. Changing the state of this switch clears
user-entered passwords stored in NVRAM, and restores default
passwords. Once you reset the MicroMMAC, you can use the defaults
or re-enter your passwords.
!
C AUT IO N
–
DO NOT change the state of Switch 6 unless
–you have a station acting as a BOOTP server, and a tftp
server that contains the MicroMMAC image file. The BOOTP
server and the tftp server could be different servers.
–you intend to set up a station to act as a BOOTP server for the
MicroMMAC.
!
C AUT IO N
Do not change the state of Switch 8 unless you want to reset
the MicroMMAC user-configured passwords to their factory
default settings.