3-1
Chapter 3
Operation
The 9M426-02 FDDI SmartSwitch Module is a three port switch module with two
front panel HSIM interfaces and one INB-2 backplane interface. This module,
with the proper HSIM, may be used for an FDDI, ATM, WAN and other
high-speed connectivity for the SmartSwitch 9000 chassis.
System Management Buses
There are two management channels within the SmartSwitch 9000 system: the
SMB-1 and the SMB-10. These buses provide out-of-band management and inter-
module management communication.
SMB-1 Bus
The SMB-1 is a 1Mbs management bus located within the SmartSwitch 9000. This
bus is utilized by all diagnostic controllers in the system including connectivity
modules, power supply modules and the environmental module. The SMB-1
transports inter-chassis information between system components, such as power
and environmental information, as well as diagnostic messages. Periodic
loop-back tests are performed by all modules which share this bus to ensure the
validity of SMB-1. In the event a failure is detected on SMB-1, the SMB-10 may be
used as an alternate communication channel.
SMB-10 Bus
The SMB-10 is a 10Mbs management bus located within the SmartSwitch 9000
which is also used for inter-chassis communication of modules as well as serving
as an out-of-band management channel into the SmartSwitch 9000. The SMB-10 is
externalized from the chassis via an optional Ethernet Port Interface Module
(EPIM) located on the front of the Environmental Module. Through an EPIM
connection, full SNMP management of the SmartSwitch 9000 is available out-of-