Chapter 5: FN10 Filters
Page 5-22
Fast Network 10 User Guide
18. Enter the field value.
19. Enter the field mask.
20. Select the operator.
Or is the default. You do not need to enter anything if the filter will
use the Or operator. If you want the filter to use the And operator, type
And
.
21. Enter the filter number.
One (1) is the default. You do not need to enter anything if the filter
number is 1.
If you want the filter to have an index number other than 1, enter the
value you want to use.
LCM displays the filter you entered and prompts you to save it. Enter y
(Yes) to save the filter, or n (No) to cancel it. If you save the filter, it is
redisplayed.
5.5.1 Modifying a Port Filter
You modify a Port filter in much the same way as you add one. LCM
prompts you through each field. To modify a Port filter, begin with the
steps below, then follow the prompts as if you were adding a filter.
At the LCM prompt:
1. Type
filters modify
LCM prompts you for the filter index (number).
2. Enter the filter index number.
LCM displays the filter type field and prompts you through the filter
fields in the same way as when you add a filter. What you had
previously entered becomes the default value and is displayed in
brackets [ ]. Make any changes you want following the instructions for
adding a filter.
Summary of Contents for Fast Network 10
Page 2: ......
Page 30: ...Chapter 1 Introduction Page 1 20 Fast Network 10 User Guide...
Page 42: ...Chapter 2 Unpacking and Installing Your FN10 Page 2 12 Fast Network 10 User Guide...
Page 80: ...Chapter 4 Monitoring and Managing Your FN10 Page 4 20 Fast Network 10 User Guide...
Page 104: ...Chapter 5 FN10 Filters Page 5 24 Fast Network 10 User Guide...
Page 118: ...Appendix A Technical Specifications Page A 6 Fast Network 10 User Guide...