CONNECTING THE RMIM/EPIM TO THE NETWORK
Installation Guide
3-11
Figure 3-7. Connecting a Thin-Net Segment to an EPIM-C
Internal Termination Switch in ON Position
2.
If the Internal Termination switch is in the ON position, connect the thin-net
segment directly to the BNC port as shown in
Figure 3-7.
3.
If the Internal Termination switch is in the OFF position:
a.
Attach a BNC tee-connector to the BNC port on the module.
b.
Attach the thin-net segment to one of the female connectors on the tee-
connector.
c.
Attach another thin-coax segment or a terminator to the other female
connector on the tee-connector.
When internal termination switch
is set to OFF:
Connect BNC tee-connector to port.
Attach a terminator or terminated
thin-net segment to one female
connector of tee-connector.
Connect a terminated thin-net
segment to other female connector
of tee-connector.
Attach thin-net segment directly to BNC
connector when internal termination
switch is set to ON.
on
of
f
Summary of Contents for CXRMIM
Page 2: ......
Page 18: ...1 10 Repeater MIM Chapter 1 INTRODUCTION...
Page 40: ...3 8 Repeater MIM Chapter 3 INSTALLING THE RMIM Figure 3 4 Installing an EPIM CXRMIM ETHERNET...
Page 58: ...4 6 Repeater MIM Chapter 4 TESTING THE RMIMS Figure 4 4 EPIM LEDs...
Page 68: ...A 10 Repeater MIM Appendix A Twisted Pair Wiring Tables...
Page 78: ...Index 4 Repeater MIM Index...