Chapter 4: LANVIEW LEDs
4-4
HSIM-F6 User’s Guide
•
Wrap-A -
The flow of the primary ring is entering through port A
(primary in) and is wrapped by the HSIM-F6, causing the ring to exit
through port A (secondary out). Port B is disconnected from the ring.
If the HSIM-F6 LED state indicates “Wrap-A” the ring has lost the
redundancy of the secondary ring due to the wrapped condition. This
configuration should be repaired, as additional problems could isolate
stations from the FDDI ring.
•
Wrap-B -
The flow of the primary ring is entering through port B
(secondary in) and is wrapped by the HSIM-F6, causing the ring to
exit through port B (primary out). Port A is disconnected from the
ring. If the HSIM-F6 LED state indicates “Wrap-B” the ring has lost
the redundancy of the secondary ring due to the wrapped condition.
This configuration should be repaired, as additional problems could
isolate stations from the FDDI ring.
•
Isolated -
Both port A and port B are isolated from the ring.
•
Dual Homed (Default) -
The flow of the primary ring is entering
through port B (primary in) and is wrapped by the HSIM-F6, causing
the ring to exit through port B (secondary out). Port A is in standby
mode, and will take over the functions of port B if port B leaves the
ring. This LED sequence is the default setting if the HSIM-F6 is
configured to be a dual homed device.
•
Dual Homed (Modified) -
The flow of the primary ring is entering
through port B (primary in) and is wrapped by the HSIM-F6, causing
the ring to exit through port B (secondary out). Port A is in standby
mode, and will take over the functions of port B if port B leaves the
ring. This dual homed LED sequence is set by setting the OID
ctsmtmibDualHomeWrpLEDStatus to off.
•
Twisted Ring (A-A, B-B) -
This condition indicates that the A port
of the HSIM-F6 is connected to the A port of another device, and the
B port of the HSIM-F6 is connected to the B port of the other device.
This is an undesirable ring condition and should be repaired as some
stations could be isolated from the primary ring.
Summary of Contents for BRIM F6 BRIM-F6
Page 1: ...HSIM F6 User s Guide A B A B P S HSIM F6 ...
Page 2: ......
Page 8: ...Notice vi HSIM F6 User s Guide ...
Page 56: ...Chapter 3 Local Management 3 32 HSIM F6 User s Guide ...
Page 62: ...Chapter 4 LANVIEW LEDs 4 6 HSIM F6 User s Guide ...
Page 70: ...Chapter 5 Specifications 5 8 HSIM F6 User s Guide ...
Page 74: ...Appendix A FPIM Specifications A 4 HSIM F6 User s Guide ...