The Ring Statistics Screen
HSIM-F6 User’s Guide
3-11
3.6.1
HSIM-F6 FDDI Ring Statistics Screen Fields
The HSIM-F6 FDDI Ring Statistics screen allows the user to monitor the
current HSIM-F6 operational status.
The following list describes the Ring Statistics screen fields:
RING STATE
Displays the current ring state. The possible ring states are as follows:
•
Ring-Op -
The ring is functioning correctly.
•
Isolated -
The HSIM-F6 is not attached to the ring.
•
Non-Op -
The HSIM-F6 is attempting to enter the ring.
•
Detect -
The claim (beacon) process of the FDDI ring
protocol has exceeded one second. There may be a
problem.
•
Non-Op-Dup -
The ring failed to complete the claim (beacon)
process. This usually indicates a duplicate FDDI
address.
•
Ring-Op-Dup -
The ring is operational, but a duplicate FDDI
address may be present somewhere on the network.
•
Directed -
The claim (beacon) process did not complete
within ten seconds. The HSIM-F6 is sending
directed beacons to indicate a problem.
•
Trace -
A problem has been detected with the HSIM-F6 or
the nearest active upstream neighbor (NAUN). A
trace is being sent to notify the nearest active
upstream neighbor of the problem.
RING-OP COUNT
The Ring-Op Count keeps track of the number of times the FDDI ring has
initialized since the last time the HSIM-F6 (or host device in which it
resides) was reset. If this number grows steadily over a brief period of
time, it signifies the ring is unstable.
Summary of Contents for BRIM F6 BRIM-F6
Page 1: ...HSIM F6 User s Guide A B A B P S HSIM F6 ...
Page 2: ......
Page 8: ...Notice vi HSIM F6 User s Guide ...
Page 56: ...Chapter 3 Local Management 3 32 HSIM F6 User s Guide ...
Page 62: ...Chapter 4 LANVIEW LEDs 4 6 HSIM F6 User s Guide ...
Page 70: ...Chapter 5 Specifications 5 8 HSIM F6 User s Guide ...
Page 74: ...Appendix A FPIM Specifications A 4 HSIM F6 User s Guide ...