What to Do If You Have Problems
7-2
Diagnosing Problems
Compare the state of the Seven-Segment Display and the System OK LED with
those shown in Table 7-1 and go to the section indicated for information on
corrective action.
Table 7-1. Display/Indications
Device
Definition
State
Indication
Corrective
Action
System OK
LED
Diagnostic
On
Self-test passed
-
Off
Fatal error
1
Page 7-3
Page 7-4
Flashing
Nonfatal error
1
1. A fatal error means that the network access server cannot function. A
nonfatal error means that the network access server can function with
reduced capability (for example, one serial port not working).
Page 7-4
Seven-Segment
Display
Status/
Diagnostic
Off
No power or
display broken
Page 7-3
“C”, “d”, “n”
SIM failure
Page 7-3
Flashing
Fatal error
Page 7-3
Page 7-4
“3”
Load request
backoff
Page 7-6
Rotating
segment
pattern
Access Server
316 software
executing
-
On power up, the seven-segment display will show an “8”. Allow about 3
minutes to elapse before determining the state of the display.
NOTE
Summary of Contents for Access Server 316
Page 1: ...9032858 Access Server 316 Hardware Owner s Manual ...
Page 2: ......
Page 6: ...Notice iv ...
Page 12: ...Preface x ...
Page 18: ...Hardware Overview 1 6 ...
Page 32: ...Cabling the Site 3 10 ...
Page 40: ...Connector and Cable Pin Descriptions 4 8 ...
Page 46: ...Replacing and Adding Memory 5 6 6 Remove the faulty SIM Figure 5 5 Figure 5 5 SIM Removal ...
Page 48: ...Replacing and Adding Memory 5 8 Figure 5 7 Adding an Additional SIM ...
Page 52: ...Replacing and Adding Memory 5 12 ...