Replacing and Adding Flash RAM
6-8
10. Reconnect the cables and test the Access Server 316.
When you plug in the power cable, the Access Server 316 runs a self-test. After
the tests are completed, the Access Server 316 requests a load from Flash
RAM. If Flash RAM is installed, three horizontal segments will be displayed.
To abort Flash RAM load and to load from the network, press and hold the
system reset switch until the display flashes. The Seven-segment display will
alternate between 3 and 4 until the software is loaded from the network.
Allow 3 minutes for the Access Server 316 to complete the procedure.
11. Compare the Seven-segment display and the System OK LED status with
Table 6-1.
12. Check the status of the Flash RAM card using the SHOW CONFIGURATION
command.
Table 6-1. LED Status
Device
Definition
State
Indication
Corrective
Action
System OK
LED
Diagnostic
On
Self-test passed
-
Off
Fatal error
1
Page 7-3
Page 7-4
Flashing
Nonfatal error
1
1. A fatal error means that the network access server cannot function. A
nonfatal error means that the network access server can function with
reduced capability (for example, one serial port not working).
Page 7-4
Seven-segment
display
Status/
Diagnostic
Off
No power or
display broken
Page 7-3
“C”, “d”, “n”
SIM failure
Page 7-3
Flashing
Fatal error
Page 7-4
“3”
Load request
backoff
Page 7-6
Rotating
segment
pattern
Access Server
316 software
executing
-
Summary of Contents for Access Server 316
Page 1: ...9032858 Access Server 316 Hardware Owner s Manual ...
Page 2: ......
Page 6: ...Notice iv ...
Page 12: ...Preface x ...
Page 18: ...Hardware Overview 1 6 ...
Page 32: ...Cabling the Site 3 10 ...
Page 40: ...Connector and Cable Pin Descriptions 4 8 ...
Page 46: ...Replacing and Adding Memory 5 6 6 Remove the faulty SIM Figure 5 5 Figure 5 5 SIM Removal ...
Page 48: ...Replacing and Adding Memory 5 8 Figure 5 7 Adding an Additional SIM ...
Page 52: ...Replacing and Adding Memory 5 12 ...