9E423-36 Module Specific 
Information

 

Introduction

 

This appendix contains local management information that is specific to the 
9E423-36 Ethernet Switch Module.

The 9E423-36 Ethernet Switch Module is a 37-port switching module with:

36 front panel Ethernet ports

1 Internal Network Bus (INB) backplane port

Each front-panel port of the 9E423-36 can be configured to operate in the Full 
Duplex mode. This configuration allows each port to provide a full 20 Mbps of 
bandwidth.

 

Modifying Fields and User Privileges

 

To modify fields on this module, you must have read-write or super-user 
privileges. If you have read-only privileges, you can view information; however, 
you cannot modify any fields. For more information about user privileges and 
community names, see the 

 

SmartSwitch 9000 Module Local Management User’s 

Guide.

Summary of Contents for 9E423-36

Page 1: ...9031943 03 SmartSwitch 9000 9E423 36 Local Management Appendix...

Page 2: ......

Page 3: ...ort Each front panel port of the 9E423 36 can be configured to operate in the Full Duplex mode This configuration allows each port to provide a full 20 Mbps of bandwidth Modifying Fields and User Priv...

Page 4: ...NET2 Ethernet Front Panel Port 2 8 ENET3 Ethernet Front Panel Port 3 9 ENET4 Ethernet Front Panel Port 4 10 ENET5 Ethernet Front Panel Port 5 11 ENET6 Ethernet Front Panel Port 6 12 ENET7 Ethernet Fro...

Page 5: ...Port 24 30 ENET25 Ethernet Front Panel Port 25 31 ENET26 Ethernet Front Panel Port 26 32 ENET27 Ethernet Front Panel Port 27 33 ENET28 Ethernet Front Panel Port 28 34 ENET29 Ethernet Front Panel Port...

Page 6: ...23 36 Firmware Revision XX XX XX Slot Number 12 BOOTPROM Revision XX XX XX PORT OPERATION MODE LINK STATUS PORT STATUS 1 STANDARD ENET No Link ENABLED 2 STANDARD ENET No Link ENABLED 3 STANDARD ENET N...

Page 7: ...at the same time Therefore the port is running at 20 Mbps LINK STATUS Read only Indicates whether there is a physical connection from this port to another 10Base T device One of the following values a...

Page 8: ...s the Return key Setting All Ports to Full Duplex To set all 36 Ethernet ports to Full Duplex 1 Use the arrow keys to highlight the SET ALL PORTS field 2 Press the Space Bar until you see FULL 3 Use t...

Page 9: ...cal Management PORT STATISTICS Module Name 9E423 36 Firmware Revision XX XX XX Slot Number 12 BOOTPROM Revision XX XX XX PORT 1 OCTETS 747881 PACKETS 5079 LINK STATUS No Link TOTAL ERRORS 0 COLLISIONS...

Page 10: ...received is the same as the data that was originally sent Alignment errors are due to misaligned packets UNDERSIZE PACKETS Read only Displays the number of packets received whose size was less than t...

Page 11: ...d port Possible values are ENABLED and DISABLED APPLICATION Read only Displays BRIDGING indicating that the port is operating as a bridge with a high speed backbone connection OPERATION MODE Read only...

Page 12: ...the bottom of the screen 2 Press the Space Bar to increment or press the Backspace key to decrement the port number 3 Press the Return key neither the read only Port field nor the statistics will cha...

Page 13: ...martTrunk Configuration screen displays Figure 3 SmartTrunk Configuration Screen SmartSwitch 9000 Local Management SmartTrunk Configuration Screen Module Name 9E423 36 Firmware Revision XX XX XX Slot...

Page 14: ...used for load sharing At least two ports must be designated as NETWORK to do load sharing SmartTrunk State Read only Displays the current operating state of the port None The trunk is operating as a...

Page 15: ...cond screen the PREVIOUS command displays To display the next screen use the arrow keys to highlight NEXT Press ENTER and the next screen of entries displays To display the previous screen use the arr...

Page 16: ...9E423 36 Module Specific Information 14...