Chapter 5: Local Management
5-76
6H122-16 User’s Guide
Section 5.22.2
describes how to download using RUNTIME.
Section 5.22.3
describes how to download using BootP.
Reboot After Download (Modifiable when RUNTIME is chosen only)
This field notifies the user that the 6H122-16 will reboot after the
download is complete. If a RUNTIME Download is performed, this field
toggles between YES and NO. If YES is selected, the module reboots
after the download is completed. If NO is selected the module continues
using the existing the firmware image. The module stores the new
firmware image in FLASH memory. When the module or 6C105 chassis
is reset, the module will boot from FLASH memory using the new image.
TFTP Gateway IP Addr (modifiable)
This field shows the IP address of the TFTP gateway server defined in the
General Configuration screen in
Section 5.15.4
.
Last Image Server IP (Read-only)
This field shows the IP address of the server used for the previous FLASH
Download.
Last Image File Name (Read-only)
This field shows the complete path and file name of the last image
downloaded to FLASH.
Download Server IP (Selectable)
The IP address of the TFTP server to be used for the FLASH download is
entered in this field.
Download File Name (Selectable)
The complete TFTP Server path and file name of the new image is entered
in this field.
5.22.1
Image File Download Using TFTP
Set the 6H122-16 to download to FLASH using TFTP as follows:
1.
Use the arrow keys to highlight the Download Method field.
NOTE
If TFTP or RUNTIME is selected as the download method
(
Figure 5-31
), the following two additional fields appear.