Page 1: ...ELECTRONIC ASSEMBLY AID QS 200S Cablescan ...

Page 2: ......

Page 3: ...March 25 2005 QS 200S INSTRUCTION MANUAL Part Number 5900159 Cablescan A Eubanks Company 3022 Inland Empire Blvd Ontario California 91764 909 483 2436 Fax 909 483 2463 www cablescan com ...

Page 4: ... and fitness for use and under no circumstances shall Cablescan Inc be liable for any incidental or consequential property damages or losses If the product is within the warranty period and requires repair for any defect of manufacture contact your Cablescan Inc representative for instructions on returning it to the factory If the product is beyond the warranty period and repair is necessary it is...

Page 5: ...rument Positioning 1 Repair 1 OPERATING CONTROLS INDICATORS 2 OPERATING INSTRUCTIONS 4 Introduction 4 Front and Rear Panel Features 4 Before Initial Power On 4 Power on Procedure Mode Selection 4 Scan Mode 4 Analyze Mode 4 Preselect Mode 4 Interface to wire Assembly 4 MAINTENANCE 5 Disassembly Assembly 5 Adjustments 5 Trouble Analysis 5 ...

Page 6: ...ed in place of existing color letter or alphanumeric designations The QS 200S is a compact self contained instrument using body conductance to allow unmatched versatility in identifying any wire at random Two hundred signal inputs are provided on four connectors of 50 pins each Contact of the probe output to any input will produce a three digit display of the number assigned to that particular inp...

Page 7: ... rate when multiple wires are present MULTIPLE WIRES At least 20 wires displayed POWER 104 to 126 V 50 60 Hz or 208 to 252 V 50 60 Hz internally selectable 4 watts maximum power OPERATING TEMPERATURE 32 F to 105 F 0 C to 40 C STORAGE TEMPERATURE 40 F to 165 F 40 C to 74 C DIMENSIONS 10 2 x 11 0 x 3 2 inches 25 9 x 27 9 x 8 2 cm WEIGHT 5 5 pounds 2 49 Kg DISPLAY 0 270 inch LED Numeric Readout Speci...

Page 8: ......

Page 9: ...he circuit breaker switch position Contact with these points may result in personal injury or death Therefore always disconnect the power cord when changing power transformer connections For the purpose of changing transformer line voltages perform the following steps to expose the power transformer a Loosen side knobs and remove handle positioner b Place instrument upside down and remove four scr...

Page 10: ... SWITCHES A set of three thumbwheel switches allows for the preselection of any wire from 001 through 200 DISPLAY A three digit visual readout of the corresponding pin on scan inputs connected to PROBE Note Decimal point to the right of the units display indicates operation in the ANALYZE mode Decimal point to the right of the hundreds display indicates a wire probed in the PRESELECT mode other th...

Page 11: ...Q S 200S E AR P H O N E V O LU M E W IR E N U M B E R P R E S E LE C T S C A N A N A LY ZE 0 4 3 P R O B E Front Panel J2 J4 J1 J3 151 200 101 150 1 50 51 100 Q S 2 00S S N X X X X Cablescan Inc Made in U S A PUSH ON Rear Panel Figure 1 ...

Page 12: ...ting multiple wires simultaneously however causes the numbers to be rapidly sequenced through This appears as a flickering of the numeric display ANALYZE MODE The ANALYZE Mode is used when the identity of multiple wires as indicated in SCAN is to be determined Depressing the ANALYZE switch sets the instrument for this purpose A decimal point light appears to the right of the display continuously t...

Page 13: ...inals The energy available at those points may result in personal injury or death if contacted ADJUSTMENTS The QS 200S has no adjustments TROUBLE ANALYSIS Trouble shooting the QS 200S will be much easier after obtaining a good basic knowledge of the instrument Trouble analysis should be undertaken only after it is established that a malfunction exists Check to be sure that the trouble is not the r...

Page 14: ...Page 6 QS 200 Instruction Manual NOTES ...

Page 15: ...5900159 Rev F Cablescan ...

Reviews: