background image

Problem

Solution

The tester does not work.  

Use the right battery with 
right polarity. Replace battery 

as described.

Which pins have to be 

connected?

Read the possible pinout 

combinations.

Other questions?

Contact your dealer or visit 

caberqu.com for more info. 

C2C caberQU

11

8. Warranty

We as the manufacturer have no influence on installation, therefore warranty of the product only applies to the 
product.

Please contact your dealer and provide your sales slip, if any fault or damage is detected on your device. 

Alternatively you can contact us directly:

Peter Traunmüller eU, Arnleitnerweg 13, 4020 Linz, AUSTRIA, Tel: +4369981148006,  E-Mail: [email protected]
Web: caberqu.com

We as the manufacturer are not liable for damages to persons or property caused by improper installation or 
operation not described in this manual.

Any  use  other  than  described  in  this  user  manual  is  not  permitted,  and  causes  loss  of  warranty,  loss  of 
guarantee, and non-liability.

We reserve our right for misprints and changes of the device, packing, or user manual.

Exclusion of liability:

The firmware and/or hardware may be changed at any time without prior notice. It is possible that parts of these 

instructions, technical data and images in this manual differ partly from the product in your possession. All points 
described  in  these  instructions  only  serve  the  purpose  of  clarification  and  must  not  inevitably  correspond  to  a 

certain situation. Legal claims cannot be made on the basis of this manual.

Troubleshooting:

Summary of Contents for C2C v3.2

Page 1: ...caberqu com Manual C2C caberQU v3 2 USB C to USB C cable tester...

Page 2: ......

Page 3: ...used by persons including children with restricted sensory physical or mental abilities or lack of experience and or knowledge unless they are supervised by a person responsible for their safety or r...

Page 4: ...is swallowed it can cause severe internal burns in just 2 hours and can lead to death If you think batteries might have been swallowed or placed inside any part of the body seek immediate medical att...

Page 5: ...ght up Pins which have a resistor attached in the cable internally will make the corresponding LED light up less intense The cable tester can not detect short circuits in between different pins specia...

Page 6: ...verted by flipping the cable at connector I If D and D are connected they only light up on one side of the tester This is for compatibility with older USB connector generations and can be inverted by...

Page 7: ...Dual lane 3 2 4 Option A VBUS GND TX1 RX1 TX1 RX1 TX2 RX2 TX2 RX2 Shield Debug Accessory Mode Option A VBUS GND D D CC1 SBU1 TX1 RX1 TX1 RX1 Shield Option B VBUS GND D D CC2 SBU2 TX2 RX2 TX2 RX2 Shie...

Page 8: ...6 USB C connector summary USB 2 data Sideband not used for USB Second high speed data USB 3 4 or Alternate Mode Configuration channel plug orientation role detection current mode USB PD communication...

Page 9: ...7 Schematics C2C caberQU 9...

Page 10: ......

Page 11: ...rqu com Web caberqu com We as the manufacturer are not liable for damages to persons or property caused by improper installation or operation not described in this manual Any use other than described...

Page 12: ...ate from the municipal waste stream via designated collection facilities appointed by the government or the local authorities You avoid environmental damage with the proper disposal Disposal of old el...

Reviews: