Audible   Alarms   

Actively   lets   you   know   if   the   unit   is   in   battery   mode,   if   the   battery   is   low,   or   if   

there   is   an   over   load   condition.   

 

High   quality   battery   

The    selection    of    high    quality    sealed    lead-­‐acid    maintenance    free    batteries   

maximises   the   life   span   of   the   battery   for   prolonged   performance   and   enhanced   

economic   benefits.   

 

Automatic   Detection   

When    the    UPS    is    turned    ON,    it    immediately    performs    an    inspection    of    the   

battery   capacity.   

 

Automatic   Voltage   Regulation   

Corrects   over   and   under-­‐voltages,   without   draining   the   battery.   This   preserves   

battery   resources   and   ensures   your   UPS   will   provide   the   optimum   runtime   and   

optimum   voltage   source   during   a   power   blackout.   

 

Surge   Protection   

Protects   hardware   from   damage   due   to   unexpected   power   surges.   

 

Automatic   Charge   

The   UPS   charges   its   battery   whenever   it   is   connected   to   utility   power.   The   UPS   

can   be   in   either   the   ON   or   OFF   mode.   

 

Auto   Restart   (Cold   Start)   

If    the    UPS    has    shutdown    during    a    battery    backup    session    due    to    discharged   

batteries,    the    UPS    will    automatically    restart    once    mains    power    has    been   

restored   to   supply   mains   power   and   recharge   the   batteries.

Summary of Contents for UPS600DV3

Page 1: ...les cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 1 Version 1 CABAC UNINTERRUPTIBLE POWER...

Page 2: ...co nz W cabac co nz 2 2 of 21 Contents General Safety Instructions 3 Conditions of Use 3 Electrical Safety 4 Safe Operating Practices 5 Battery Information 7 Introduction 8 Performance 8 Installation...

Page 3: ...in hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent Conditions of Use This equipment is de...

Page 4: ...e UPS cover It may contain hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent 1 The Cabac UP...

Page 5: ...nication port are kept separated by at least 25 mm from the power cords to and from the UPS input and output Safe Operating Practices This pluggable type A equipment has factory installed batteries an...

Page 6: ...P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 6 6 of 21 disconnected 5 Turn off and unplug your UPS from the outlet and contact your nominated service agent if o The power cord or plu...

Page 7: ...o the skin and eyes 3 A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other...

Page 8: ...r is used as the main controller that renders the product an intelligent UPS capable of self protection and fault diagnosis A built in AVR function automatically adjusts itself to maintain a power sup...

Page 9: ...ction When the UPS is turned ON it immediately performs an inspection of the battery capacity Automatic Voltage Regulation Corrects over and under voltages without draining the battery This preserves...

Page 10: ...temperature and humidity is outside the specified limits in the Specifications Table 3 Connect to Mains Power Connect the AC input power cord to a socket outlet to power up the UPS The battery in the...

Page 11: ...cabac co nz W cabac co nz 11 11 of 21 Physical Appearance Front Panel Rear Panel Item Description 1 On Off Power Switch 2 LED 1 GREEN AC Normal Status LED 3 LED 2 YELLOW Battery Charging LED 4 LED 3 R...

Page 12: ...dicators Front Panel Indicator Buzzer Status Operational Description LED 1 Green LED2 Yellow LED 3 Red OFF ON OFF OFF UPS OFF Mains Normal Batteries Charging ON ON OFF 2 second Interval Beeping UPS ON...

Page 13: ...s the power switch to stop the beeping The alarm stops when the UPS returns to normal utility mode of operation Low Battery Beeping 2 times every 1 second In Backup mode when the battery energy runs l...

Page 14: ...750W Input Characteristics Rated Input Voltage 230 240V Input Voltage Range 165 275 V Rated Input Frequency 50 Hz 10 Output Characteristics Rated Output Voltage 230V 10 Output Frequency 50 Hz 10 Outpu...

Page 15: ...mm x 124mm x 382mm Operating Temperature 10 C to 40 C Maximum Operating Relative Humidity 95 Relative Maintenance 1 With normal use a UPS battery will last 2 to 3 years depending on the number of disc...

Page 16: ...es cabac co nz W cabac co nz 16 16 of 21 Software Installation In order to utilise the UPS to its full potential the monitoring software must first be installed Please install the software according t...

Page 17: ...stribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 17 17 of 21 3 Enter details as requested on this screen Your product serial n...

Page 18: ...sales cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 18 18 of 21 5 Select language English...

Page 19: ...8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 19 19 of 21 7 Installation is now complete Click FINISH 8 The program is...

Page 20: ...No LED s on i Battery Discharged Sleep Mode Press the POWER button ON ii PCB failure Contact Service Agent UPS always at battery mode Power cord lose Re plug the power cord Line voltage too high too l...

Reviews: