CAB HYDRO HD.3524E Manual Download Page 8

11

EN

ENG

WARNING

GENERAL INFORMATIONS

The product shall not be used for purposes or in ways other than those for which the product is intended for and as described 
in this manual.
Incorrect uses can damage the product and cause injuries and damages.
The company shall not be deemed responsible for the non-compliance with a good manufacture technique of gates as well 
as for any deformation, which might occur during use.
Keep this manual for further use. 

INSTALLER GUIDE

This manual has been especially written to be use by qualified fitters.
Installation must be carried out by qualified personnel (professional installer, according to EN 12635), in compliance with 
Good Practice and current code. 
Make sure that the structure of the gate is suitable for automation. 
The installer must supply all information on the automatic, manual and emergency operation of the automatic system and 
supply the end user with instructions for use.

GENERAL WARNINGS

Packaging must be kept out of reach of children, as it can be hazardous. 
For disposal, packaging must be divided the various types of waste (e.g. carton board, polystyrene) in compliance with 
regulations in force.
Do not allow children to play with the fixed control devices of the product. 
Keep the remote controls out of reach of children. 
This product is not to be used by persons (including children) with reduced physical, sensory or mental capacity, or who are 
unfamiliar with such equipment, unless under the supervision of or following training by persons responsible for their safety.
Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and 
shearing hazard.
Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the 
operating logic of the system and forces generated by the automated system. 
Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453. 
Only use original accessories and spare parts, use of non-original spare parts will cause the warranty planned to cover the 
products to become null and void.
All the mechanical and electrical parts composing automation must meet the requirements of the standards in force and 
outlined by CE marking.

ELECTRICAL SAFETY

An omnipolar switch/section switch with remote contact opening equal to, or higher than 3mm must be provided on the 
power supply mains.
Make sure that before wiring an adequate differential switch and an overcurrent protection is provided.
Pursuant to safety regulations in force, some types of installation require that the gate connection be earthed. 
During installation, maintenance and repair, cut off power supply before accessing to live parts. 
Also disconnect buffer batteries, if any are connected. 
The electrical installation and the operating logic must comply with the regulations in force.
The leads fed with different voltages must be physically separate, or they must be suitably insulated with additional insulation 
of at least 1 mm. 
The leads must be secured with an additional fixture near the terminals.
During installation, maintenance and repair, interrupt the power supply before opening the lid to access the electrical parts
Check all the connections again before switching on the power.
The unused N.C. inputs must be bridged.

WASTE DISPOSAL

As indicated by the symbol shown, it is forbidden to dispose this product as normal urban waste as some parts might be 
harmful for environment and human health, if they are disposed of incorrectly. 
Therefore, the device should be disposed in special collection platforms or given back to the reseller if a new and similar 
device is purchased.
An incorrect disposal of the device  will result in fines applied to the user, as provided for by regulations in force.

Descriptions and figures in this manual are not binding.
While leaving the essential characteristics of the product unchanged, the manufacturer reserves the right to modify the same under the 
technical, design or commercial point of view without necessarily update this manual.

Summary of Contents for HYDRO HD.3524E

Page 1: ...CL8542450 10 2018 rev 2 HYDRO HD 3524E HD 3524E AC HD 5024E HD 5024E AC IT EN DE FR ES PL...

Page 2: ...indicatif d ouverture ralentissement exclu Tiempo indicativo de abiertura deceleraci n excluido Wskazuj cy czas otwierania wy czy zwalniaj 1177 HD 3524 1417 HD 5024 120 Mettere a livello Level Nivell...

Page 3: ...chlag zur Schlie ung Arr t en fermeture Tope de cierre Chwytak blokuj cy podczas zamykania Arresto in apertura Stop when opening Endanschlag zur ffnung Arr t en ouverture Tope en apertura Chwytak blok...

Page 4: ...t souder Cortar a medida y soldar Wyci wed ug rozmiaru i zespawa Grasso Grease Fett Graisse Grasa Smar 8 max 290mm HD 35 max 410mm HD 50 min 20mm 6 7 Anta sinistra Left hand wing Linker Fl gel Vantail...

Page 5: ...5 Anta sinistra Left hand wing Linker Fl gel Vantail gauche Hoja izquierda Skrzyd o lewe Anta destra Right hand wing Rechter Fl gel Vantail droit Hoja derecha Skrzyd o prawe 11 12 9 1 2 10...

Page 6: ...sheath Spiralmantel 12 Gaine spiral e 12 Vaina corrugada 12 Os ona spiralna 12 K R B G W K R B G W ENC ENC ENC M 24 M 24 Bianco White Wei Blanc Blanco Bia y Verde Green Gr n Vert Verde Zielony Marrone...

Page 7: ...7 15 Livello olio Oil level lstand Niveau d huile Nivel de aceite Poziom oleju...

Page 8: ...tandards EN 12978 and EN 12453 Only use original accessories and spare parts use of non original spare parts will cause the warranty planned to cover the products to become null and void All the mecha...

Page 9: ...tions supplied with the central unit for further information 2 TECHNICAL DATA MODEL HD 3524E HD 3524E AC HD 5024E HD 5024E AC Power supply 24 Vdc Motor 240 W Absorbed current 5 A Protection rating IP5...

Page 10: ...heck it moves freely to fully open and stops on the gate stop The wing must move smoothly and evenly 9 Anchor the bracket permanently NOTE Vent plug fig 12 Next to the vent a dead hole has been provid...

Page 11: ...26 1 2 33 14 4 3 5 7 8 12 26 27 28 32 24 18 13 9 10 11 15 16 17 19 6 A B D F C 25 31 30 E G 20 H 21 23 29 22 15 34...

Page 12: ...erno snodo Pivot lock pin Gelenkbolzen Pivot articul Perno articul Sworze przegubu CF8621022 14 Tappo olio Oil cap lstopfen Bouchon huile Tap n de aceite Korek wlewu oleju CF8837055 15 Serbatoio Tank...

Page 13: ...a marcatura CE della macchina e l utilizzo di componenti originali CAB Libro istruzioni per l utilizzatore User s handbook Aprire lo sportellino per acceddere alla manopola di sblocco Open the protect...

Page 14: ...ung kann bei folgender Adresse angefordert werden Automatismi CAB Srl Vel d Astico VI ITALY D claration CE de conformit DoC Nom du producteur Automatismi CAB Srl Adresse Via della Tecnica 10 z i 36010...

Page 15: ...AUTOMATISMI CAB Srl Via della Tecnica 10 z i 36010 Velo d Astico VI Italia Tel 0445 741215 Fax 0445 742094 info automatismicab com www automatismicab com...

Reviews: