Mounting the Pad
1
2
4
5
6
8
7
3
Fig. 14
Mounting the pad
1. Insert the pin (6) on the pad (8) into the hole on the bottom side of the pad holder (7).
2. Fix the pad (8) with the screw (1) at the pad holder (7).
3. Insert the vacuum tube (2) and the blowing air tube (3) into the appropriate push-in-fittings (4,5) of the pad.
!
Attention!
To avoid possible collisions of the pad with other parts of the printer-applicator system, please roughly
align the pad in all directions (
"Mechanical Adjustments") before connecting the applicator to the
compressed air supply !
3.6
Mounting the Stopper for the Application Mode "Blow"
1 2 3
1
3
4
4
3
1
3
1
2
former Version
current Version
Fig. 15
Mounting the stopper
When the applicator is delivered, the stopper (1) is mounted on the rods (4). With this stopper the labelling position
for the operation mode "Blow on" can be adjusted. In delivery status the stopper is in a transport safety position.
Dependent of delivery time it's two different version of stopper. The function are the same.
In the operation modes "Stamp on" and "Roll on" the stopper is not needed, the stopper will moved in the top position
so far as possible.
Mounting the stopper
1. Loosen screw (3) at the stopper (1) .
2. Pull the tubes out of the lift cylinder throttle valves.
3. Move the tamp in the labeling position.
- Operation mode "Blow" : Move stopper to the guiding block.
- Operation Mode "Stamp" and "Roll" : Move the stopper up to the end of the rods (4).
4. Tighten screw (3) to fix the stopper (1) position.