10
11
5
6
Fig. 6
Adjusting the Parallelism
4. Loosen knurled screw and press the applicator against the printer.
5. Adjust the angle between applicator pad edge and printer dispensing plate via the eccentric (5).
6. By turning setting screw (6) the tamp assembly in a horizontal angle to the printer.
7. By turning setting screw (1) the tamp assembly moves up or down. Turn the screw until the dispensing plate and
the suction plate are about 1 mm apart.
1 mm
1 mm
Fig. 7
Adjusting the height of the air-jet module