CA.MI NEW ASKIR 30 User Manual Download Page 10

 

10 

 

NEW ASKIR 30

 it’s a device working with 230V ~ / 50 Hz network electricity, to be used for the nasal aspiration, oral 

aspiration, tracheal aspiration of the body liquids (mucus or catarrh) in the adult or in the children. 
Easily transportable from one hospital ward to another, particularly suitable for tracheotomized patients, minor surgical 
applications and post-operative therapy at home.  
Easily portable equipment designed for not continuous use 120 min. ON / 60 min. OFF. Made of highly heat-resistant, 
electrically insulated plastic material in conformity with the latest European safety standards. 
Supplied with a complete polycarbonate autoclavable jar complete with overflow valve. 
Equipped with aspiration regulator and vacuum indicator located on the front panel. 
 

GENERAL WARNING 

 

 

READ INSTRUCTION MANUAL CAREFULLY BEFORE USE 

 

ONLY HIGHLY QUALIFIED STAFF USE RESERVED 
 
THE  INSTRUMENT MUST NOT BE DISASSEMBLED 
FOR A TECHNICAL SERVICE ALWAYS CONTACT CA-MI 

 

IMPORTANT SAFETY RULES 

 

1.

 

On opening the packaging, check the integrity of the appliance, paying particular attention to the presence of 
damage to the plastic parts, which may make access possible to internal live parts and also to breakage and / 
or peeling of the power supply cable. 

In these cases don’t connect the plug to the electric socket.                                

Carry out these controls before each use;

 

2.

 

before connecting the appliance always check that the electric data indicated on the data label and the type of 
plug used, correspond to those of the mains electricity to witch it’s to be connected; 

3.

 

If the plug supplied with the appliance is incompatible with the mains electricity socket, contact qualified staff for 
replacement of the plug with a suitable type. The use of simple or multiple and / or extension adapters is not 
generally recommended. Whenever their use is indispensable, use those in compliance with safety regulations, 
however paying attention not to exceed the maximum power supply limits, which are indicated on the adapters 
and extensions; 

4.

 

Respect the safety regulations indicated for electrical appliances and particularly: 

 

Only use original accessories and components; 

 

The device can be used only with the bacteriological filter; 

 

Never immerge the appliance into water; 

 

Position the appliance on flat stable surfaces; 

 

Position the device  in a way that the air inlets on the back aren’t obstructed; 

 

Never use the device in environments which have anaesthetic mixtures inflammable with air, oxygen or 

nitric  oxide; 

 

Don’t touch the device with wet hands and always prevent the appliance coming into contact with liquids; 

 

Keep off the reach of children or not capable people without supervision; 

 

Don’t leave the appliance connected to the power supply socket when not in use; 

 

Don’t pull the power supply cable to disconnect the plug remove the plug from the mains socket 

correctly; 

 

Preserve and use the medical device in environments protected from atmospheric factors and at a 

distance from heat sources; 

5.

 

For repairs, exclusively contact CA-MI technical service and request the use of original spare parts.                                                                                          
Failure to comply with the above can jeopardise the safety of the device;

 

6.

 

This medical device must be destined exclusively for the use for witch it has been designed ad described 
in this manual. 

Any different use must be considered incorrect and therefore dangerous; the manufacturer 

cannot be considered liable for damage caused by improper, incorrect and / or unreasonable use or if the 
appliance is used in electrical plants that are not in compliance with the regulations in force; 

7.

 

Particular precautions must be made concerning electromagnetic compatibility. The medical device must be 
installed and used according to information supplied with the accompanying documents; 

8.

 

Instrument and accessories discharging must be done following current law regulations in every country of use.

 

 

 
 
 
 

 

 

 

Summary of Contents for NEW ASKIR 30

Page 1: ...3010 Pilastro PR Tel 39 0521 637133 631138 Fax 39 0521 639041 E mail vendite ca mi it export ca mi it ASPIRATORE NEW ASKIR 30 ASPIRATOR NEW ASKIR 30 ASPIRATEUR NEW ASKIR 30 ABSAUGER NEW ASKIR 30 ASPIR...

Page 2: ...aupr s des revendeurs assurant ce service liminer s paratement un appareil permet d viter les retomb es n gatives pour l environement et la sant d rivant d une limination encorrecte et permet de r cu...

Page 3: ...onformi alle norme di sicurezza facendo comunque attenzione a non superare i limiti massimi di alimentazione sopportati che sono indicati sugli adattatori e sulle prolunghe 4 Rispettare le norme di si...

Page 4: ...DI ESERCIZIO Temperatura ambiente 5 35 C Percentuale umidit ambiente 30 75 RH Altitudine 0 2000m s l m CONDIZIONI DI CONSERVAZIONE E TRASPORTO Temperatura ambiente 40 70 C Percentuale umidit ambiente...

Page 5: ...Cliente e o l utente dell aspiratore chirurgico NEW ASKIR 30 devono assicurarsi che l apparecchio sia utilizzato in tale ambiente Test di Emissione Livello di prova Guida all ambiente elettromagnetico...

Page 6: ...arte conica con 3 aperture 3 Dopo aver tolto la gabbietta il galleggiante con guarnizione rossa rimosso da tappo vaso 4 Per disinfettare gli accessori utilizzare alcool denaturato o soluzione a base d...

Page 7: ...vitare a fondo il coperchio del vaso 2 Mancata aspirazione Guarnizione del coperchio non in sede Svitare il coperchio e riposizionare la guarnizione nella sede del coperchio 3 Galleggiante bloccato In...

Page 8: ...lizzato su un piano di funzionamento orizzontale Collegare il tubo lungo in silicone 4 al bocchettone 5 del coperchio rimasto libero All estremit rimasta libera del tubo lungo in silicone 1 collegare...

Page 9: ...udicata causa di un cattivo funzionamento CA MI provveder alla sostituzione del prodotto solo se provvisto in allegato di SCONTRINO e GARANZIA TIMBRATA CA MI non risponde degli accessori che presentan...

Page 10: ...use those in compliance with safety regulations however paying attention not to exceed the maximum power supply limits which are indicated on the adapters and extensions 4 Respect the safety regulatio...

Page 11: ...out jar 40 l min WEIGHT 3 6 Kg SIZE 350 x 210 x 180mm DUTY CYCLE to 35 C and 110 operating voltage 120min ON 60min OFF WORKING CONDITION Room temperature 10 40 C Room humidity percentage 20 85 RH Alti...

Page 12: ...or the user of the surgical aspirator NEW ASKIR 30 should assure that it s used in such an environment Immunity Test Compliance Electromagnetic environments guidance Electrostatic discharge ESD IEC E...

Page 13: ...fect the accessories use either denatured alcohol or hypochlorate based solutions easily purchasable from chemist shops 5 Once cleaning has been completed insert the float in the cage with the seal fa...

Page 14: ...rew the cap and insert the seal properly in its seat 3 The float doesn t close If the cap has been washed ensure that the float is not partially detached Insert the float into it s place 4 The float d...

Page 15: ...inside the device The device must be used on a plan of horizontal operation Connect the long silicon tube 4 to the other jar s lid connector 5 Connect the other end of the long silicon tube 4 to the p...

Page 16: ...unctioning or misuse If contamination is due to bad functioning CA MI will substitute the instrument only if a SALE RECEIPT and STAMPED GUARANTEE accompany the same CA MI is not responsable for contam...

Page 17: ...ant toutefois attention ne pas d passer les limites maximales d alimentation support es qui sont indiqu es sur les adaptateurs et sur les rallonges 4 Respecter les normes de s curit indiqu es pour les...

Page 18: ...IDS 3 6 kg DIMENSIONS 350 x 210 x 180mm FONCTIONNEMENT 35 C 110 alimentation letrique 120 ON 60 OFF CONDITIONS DE SERVICE Temp rature ambiante 5 35 C Pourcentage humidit ambiante 30 75 RH Altitude 0 2...

Page 19: ...utilisateur de l aspirateur NEW ASKIR 30 doivent s assurer que l appareil est utilise dans un tel environnement Test d Emission Niveau de test Guide l environnement lectromagn tique D scharges lectro...

Page 20: ...avoir enlev la cage le flotteur avec joint rouge doit tre enlev du couvercle du bocal 4 Pour d sinfecter les accessoires utiliser de l alcool d natur ou une solution base d hypochlorite 5 Apr s nettoy...

Page 21: ...le 2 L appareil n aspire pas Joint du couvercle pas en place D visser le couvercle et remettre le joint en place 3 Le flotteur bloqu Pr sence des incrustations sur le flotteur D visser le couvercle et...

Page 22: ...pareil sur des surfaces plates Brancher le tube long en silicone 4 l embout 5 du couvercle rest libre Brancher le raccord conique pour les sondes l extr mit libre du tube long en silicone 4 et ensuite...

Page 23: ...une cause de mauvais fonctionnement CA MI remplacera le produit seulement si muni du TICKET de CAISSE et de la GARANTIE avec CACHET de validation CA MI n est pas responsable des accessoires qui pr se...

Page 24: ...mnetzes entsprechen an das man das Ger t anschlie en will 3 Besonders auf folgendes achten Nur Originalzubeh r verwenden Das Ger t darf nur mit dem Backerienfilter verwendet werden Das Ger t auf einer...

Page 25: ...ften Betrieb oder falsche Benutzung ist Wenn die Kontamination als Ursache f r einen gest rten Betrieb angesehen wird nimmt CA MI der Ersatz des Produkts nur dann vor wenn ddie Rechnung oder die abges...

Page 26: ...Flasche 40 kPa 0 40 bar Max Saugleistung nie Flasche 40 l min Gewicht 3 6 kg Betrieb 35 C 110 Netzspannung 120 min ON 60 min OFF Abmessungen 350 x 210 x 180mm Betriebsbedingungen Raumtemperatur 5 35 C...

Page 27: ...nutzer des Absauger m ssen sich vergewissern dass das Ger t unter diesen Bedingungen benutzt wird Emissionstests Pr fniveau Elektromagn Umgebung Elektrosatische Entladungen ESD IEC EN 61000 4 2 6kV be...

Page 28: ...el befindet konisches Teil mit 3 ffnungen 3 Nach dem Entfernen des K figs wird der Schwimmer mit der roten Dichtung vom Beh lterverschlu entfernt 4 Zum Desinfizieren der Zubeh rteile ein handels blich...

Page 29: ...l sen und dann richtig aufschrauben 2 Keine Absaugung Stopfendichtung sitzt falsch Stopfen abschrauben und Dichtung richtig anbringen 3 Fehlener Verschlu des Schwimmers Nachdem der Stopfen gereinigt...

Page 30: ...hlauch 4 am noch freien Stutzen 5 des Deckels anschlie en Am freien Ende von Schlauch 4 den konischen Anschluss 6 f r den Katheteranschluss anschlie en und dann den Absaugkatheter darauf stecken Das N...

Page 31: ...aparato comprobar siempre que los datos el ctricos indicados en la etiqueta de los datos y el tipo de enchufe utilizado correspondan a los de la red el ctrica a la cual se conectar 3 En el caso que el...

Page 32: ...ALUD DE TODAS LAS PERSONAS QUE OPERAN PARA OBTENER CALIDAD Y BENESTAR Todo aparato enviado a CA MI ser sometido a controles higi nicos antes de la reparaci n Si CA MI juzga el aparato no id neo para l...

Page 33: ...40 l min Peso 3 6 Kg Dimensi n 350 x 210 x 180mm Funcionamiento 120 min ON 60 min OFF Condiciones de funcionamiento Temperatura ambiente 5 35 C Porcentaje de humedad ambiente 30 75 RH Altitud 0 2000m...

Page 34: ...ca a continuaci n El cliente y o el usuario del aspirador NEW ASKIR 30deben asegurarse que el aparato se utilice en dicho tipo de ambiente Test de Inmunidad Test de Inmunidad Test de Inmunidad Descarg...

Page 35: ...a se quitar el flotante con junta roja del tap n vaso 4 Para desinfectar los accesorios utilizar alcohol desnaturalizado o soluci n a base de hipoclorito 5 Finalizada la limpieza introducir el flotant...

Page 36: ...que la tapa y vuelvala a enroscar correctamente 2 Falta aspiraci n Junta del tap n fuera del alojamiento Desenroscar el tap n y acomodar la junta en su alojamiento 3 Falta cierre del flotante Si el ta...

Page 37: ...e silicona 4 en la abertura 5 de la tapa del vaso que quedo libre En la extremidad que queda libre del tubo largo de silicona 4 conectar la uni n c nica para la conexi n de sondas y por ltimo la sonda...

Page 38: ...W DIRECTION Montaggio Filtro Filter Assembling Mod NEW HOSPIVAC 400 Cod SP 0047 NEW HOSPIVAC 350 NEW ASKIR C30 Cod SP 0121 DIREZIONE FLUSSO FLOW DIRECTION IN Fluid Inside Connessione apparecchio Sucti...

Page 39: ...cal Service results defective The product must be accompanied by a description of the defect The warranty with exclusion of responsibility for direct and indirect damages it is thought limited to the...

Page 40: ...it Place ________________________________________________________________________________________________ Venduto A Purchased By _______________________________________________________________________...

Reviews: