Note:
It is recommended to consult a physician if at the end of measuring appear symbol of
Irregular Heartbeat (Arytmia) or if values are in red range of colour scale.
7. The measuring results will be shown automatically on the LCD until when the ON/OFF
button is pushed again or till automatic switch off 3 minutes later. During the same time,
the symbols will flash to remind the user to record the reading.
8. When the reading results are displaied, press M1 or M2 buttons to record data in the
Memory Set.
9. This device has average function. Press M1 or M2 to display the average of last three
measurements so to help you to get your blood pressure values more correctly (under
symbol of memory appears A indication that means that values on LCD is the average
of last three measurements).
5.5 FAST INTERRUPTION DURING A MEASUREMENT
If it is necessary to interrupt a blood pressure measurement for any reason (e.g. the patient
feels unwell), the ON/OFF button can simply be pressed at any time. The device immediately
reduces the cuff pressure.
5.6 MEMORY - DISPLAYING THE LAST MEASUREMENT
The device can store twin 90 sets (total of 180 sets) of recorded data, and each set data includes
values of diastolic and systolic pressure, pulse rate and date/time, symbols of readings.
After turning on the device by pressing the ON / OFF button, when M1 button is pressed will be
displayed symbol for memory channel M1 and the A letter (average) together average values of
last three measurements recorder on Memory 1. To go on to read values of any measurement, press
again M1 button, one time for any Regular Heart Beat Irregular heart beat measurement (on the
display will be displayed the record number of any measurement recorded, by more recently 01 to
more old 02, 03 etc...). To see the record of memory channel M2 proceed with same procedure used
for M1 but pressing M2 button. In this case will be displayed symbol .
Note
: when memories are full, the more old values will be erased one to one, starting by more
old, when you record a new measurement. To erase all records on one of two memory channels you
must press for 5 second at least the button of memory you want erase. When data are erased on LCD
will be displayed Clr indication together the symbol of memory erased ( for M1 and for M2).
FURTHER INFORMATION
Measurements should not occur soon after each other, since otherwise, the results will be
falsified. Wait therefore for several minutes (at least 15 min.) in a relaxed position, sitting
or lying, before repeating a measurement.
6. CARE, STORAGE AND REPAIR
1. It’s necessary to protect this device against high moisture and heat, direct sunlight, shock,
solvents, alcohol.
2. Remove the batteries if the device will be unused for a long time, and keep the batteries
out of the reach of children.
3. Keep the cuff away from sharp subjects and don’t extend or twist the cuff.
4. Use only soft and dry cloth to clean the device.
5. The cuff is delicate and must be handled with care. You can clean the cuff cover with
damp cloth.
Warning: under no circumstances any part of device and its accessories could be washed.
Keep the device and all of its accessories out of the reach of children.
29