C-TEC QT606A Manual Download Page 16

Approved Document No: DNSQ100101 Rev 6 • Page 16 of 16

C-TEC, Stephens Way, Wigan WN3 6PH. United Kingdom.

© 1996-2005.  Approved Document No: DNSQ100101 Rev 6. We reserve the right to alter product  specifications
at our discretion and without prior notice.  Errors and omissions excepted.  This guide has been carefully
checked prior to publication. However, no responsibility can be accepted by the Manufacturer or Distributor(s)
of the Quantec system for any inaccuracies or for any misinterpretation of an instruction or guidance note.

UK Sales:

Tel: 01942 322744
Fax: 01942 829867
E-Mail: [email protected]

European Sales:

Tel: +44 1942 322744
Fax: +44 1942 829867
E-Mail: [email protected]

Export Sales:

Tel: +44 161 257 2541
Fax: +44 161 225 8817
E-Mail: [email protected]

Website:

www.c-tec.co.uk

Summary of Contents for QT606A

Page 1: ...A GUIDE TO Quantec Approved Document No DNSQ100101 Rev 6 Page 1 of 16 a d d r e s s a b l e c a l l s y s t e m...

Page 2: ...s 6 Displays 7 Infrared ceiling receivers 7 Radio receivers 7 RF integrity transmitters 7 Addressable overdoor lights addressable sounders 8 Quantec controller 8 ANCILLARY DEVICES 9 Slave overdoor lig...

Page 3: ...anning and displays can be fitted virtually anywhere to suit the application However whilst simplifying things for the installer some addressable systems still fail to satisfy the varied needs of the...

Page 4: ...ting them to visit a display RESET As the member of staff leaves the room the call point s RESET button is pressed again to take it out of Staff Presence mode and returning it to normal If preferred m...

Page 5: ...C DIVERT If a call remains unanswered for a preset time 1 8 mins to ensure it does not remain unattended indefinitely the system can be set up to automatically divert it to other areas MANUAL DIVERT I...

Page 6: ...sounder QT602R Quantec call point button reset with I R receiver QT602RS Quantec call point button reset with sounder I R receiver QT602M Quantec call point magnetic reset QT602SM Quantec call point m...

Page 7: ...eivers are designed for use with Quantec s QT412 range of dual action infrared radio transmitters see page 10 Dependent on the transmitter s used they allow standard and or attack calls to be made fro...

Page 8: ...the Controller for assigning to network devices The library of 45 pre set names consists of the following Annex Area Bathroom Bedroom Conservatory Corridor Dining room Disabled WC Display Door Doorbel...

Page 9: ...esigned for use in areas such as double bedrooms where more than one call button may be required All calls must be reset at the master QT602D Quantec Slave Call Point TAIL CALL BUTTONS Tail call butto...

Page 10: ...dual site QT412RXA Dual action infrared radio transmitter configuredforpushforattack pullforattack QT412RXCA Dual action infrared radio transmitter configured for push for call pull for attack QT424 1...

Page 11: ...ted to When deciding on the position of Infrared Ceiling Receivers take into account the 10 metres line of sight transmitting range of infrared transmitters Use slave receivers in large open areas lon...

Page 12: ...ed in four or six core security cable In excess of 60 addressable devices can be connected to each network splitter Consequently four splitters are capable of accommodating an entire system However fo...

Page 13: ...e stranded alarm cable Max 3 x QT302RXs per master ceiling receiver A maximum of 10 network devices can be connected to each of the QT603s 6 outputs 240V a c QT600P Printer Kit wall socket lead pre te...

Page 14: ...410mm 250mm 80mm Quantec controller lid 439mm 274mm 7mm Radio receivers 271mm 155mm 170mm All single gang devices 87mm x 87mm mount on 25mm single gang UK back boxes All double gang devices 146mm x 8...

Page 15: ...o offer an in depth understanding of the installation maintenance and commissioning of the Quantec addressable call system Held regularly at the manufacturer s headquarters in the north west of Englan...

Page 16: ...een carefully checked prior to publication However no responsibility can be accepted by the Manufacturer or Distributor s of the Quantec system for any inaccuracies or for any misinterpretation of an...

Reviews: