Using the Generator/ Transmitter:
Batteries Alkaline and Rechargeable
C.Scope Generators/ Transmitters can be powered
by either four standard alkaline or by four standard
rechargeable Nickel-Metal Hydride (NiMH) D
(
LR20
)
size batteries.
Battery Check
Switch the Generator/ Transmitter on by pressing the
On/Off switch. The Generator/ Transmitter should emit
a loud continuous tone or a regular pulsed tone. If the
batteries need replacing or recharging an interrupted
tone will be heard.
During use, the Generator/ Transmitter will also warn the
Locator user of low battery status by altering its normal
continuous or pulsed signal output to a distinct interrupted
signal output.
(
SGV2 Generator and MXT2 Transmitter only:
Check the Battery Level Indicator in the
bottom left hand corner of the display.
If there is only one segment or no segments
of the indicator filled in then the batteries
will need to be renewed or recharged before
locating work can begin.
)
Changing the Batteries
Remove the Accessory Tray.
Undo the two round, knurled retaining screws situated
on the underside of the Generator/ Transmitter holding
the Battery Cover.
Remove ALL FOUR used batteries and replace with
new ones.
Be careful to insert the new batteries the correct way
round in the compartment as indicated on the case.
Replace the Battery Cover being careful to not over
tighten the retaining screws.
Replace the Accessory Tray.
WARNING
Do not change batteries in confined spaces where gas may be present.
WARNING
Do not mix old and new or different types of batteries.
NOTE
Only use alkaline or Nickel-Metal Hydride (NiMH) rechargeable D
(
LR20
)
size batteries.
NOTE
Dispose of the used batteries safely in accordance with local regulations.
24
Battery Levels OK
replace / recharge
batteries