11.4 Two devices interconnected and interlocked – Two doors
The connection, as shown below, is for two doors. Each door has one device and one lock. The
interlock function must be turned on in the settings. When either door is unlocked and opened, it
must be shut before the other door can be opened. This function is mainly used in banks, prisons
and other places that require high security, with two doors fitted for one access route.
11.4 Two devices interconnected with anti-passback – Two doors
Install one device on door 1 under anti-passback subsidiary mode. Install one device on door 2
under anti-passback host mode. This function mainly applies for one way in and out systems. Users
must present card on the subsidiary device to enter and on the host device to exit every time, to
ensure the enter and exit legally. Users cannot enter or exit 2 times continuously.