background image

 

7.

 

Factory reset & set management cards 

Turn off power to the unit. Connect the two pink wires then power on. After the beep, the factory reset is 
complete and the LED will turn green. Now it is necessary to learn the admin cards again. Read the first 
card as the admin add card, and the second card as the admin delete card. 

Note: Factory reset does not delete user data. 

8.

 

Sound & light indication 

Operation 

LED indicator 

Buzzer 

Initialisation 

Orange 

Didi 

Standby 

Red flash 

 

Valid button press 

 

Di 

Enter programming 

Red solid 

Di 

Setting 

Orange 

Di 

Exit programming 

Red flash 

Di 

Operation failed 

 

Didi 

Lock open 

Green 

Di 

Alarm 

Quick red flash 

Alarm 

Add sequential Card No. 

Quick green flash 

 

 

9.

 

Programming 

9.1  Managing users via admin card 

 

9.1.1  Add user via admin card 

 

.

Read admin add card

.

  

.

Read user card 1

.

  

.

Read user card 2

.

  …  

.

Read admin add card

  

9.1.2  Delete user via admin card 

 

.

Read admin delete card

.

  

.

Read user card 1

.

  

.

Read user card 2

.

  …  

.

Read admin delete 

card

 

 

9.2  Enter into programming mode (remote control) 

 

.

*

.  .

Master code

.  .

#

.   

Default master code is 999999 

All the steps below must be done after entering into programming mode. 

9.3  Change the master code 

 

.

0

.  .

New master code

.  .

#

.  .

New master code

.  .

#

.   

9.4  Add users by remote control 

 

9.4.1  Read card to add user 

 

.

1

.  .

Read card 1

.  .

#

.  .

Read card 2

.  .

#

 …  

.

#

9.4.2  Use card number to add user 

 

.

1

.  .

Card number

.  .

#

.  .

Card number

.  .

#

 …  

.

#

Note: Multiple cards can be added without exiting programming mode. Card number digits must be 8 or 10 
digits, if the card number is less than 8 or 10 digits, input 0 before the card number. 

9.4.3  Add sequential card numbers 

 

.

1

.  .

Card quantity

.  .

#

.  .

First card number

.  .

#

.

 

Add consecutive number card users, card quantity 1-9999. Fast green flash to confirm. 

9.5  Delete users by remote control 

 

9.5.1  Read card to delete user 

 

.

2

.  .

Read card 1

.  .

#

.  .

Read card 2

.  .

#

 …  

.

#

Summary of Contents for PN10

Page 1: ...inc Quantek 59 Sheffield Road Dronfield S18 2GF 44 0 1246 417113 sales cproxltd com www quantek co uk Access Control Proximity Reader PN10 User Manual Please read the manual carefully before installi...

Page 2: ...lost cards Two units can also be interlocked It has low power consumption anti theft alarm and door release button all these make it convenient safe and reliable 3 Features Zinc alloy anti vandal she...

Page 3: ...it the reader into the back plate and replace retaining screw 6 Wiring Colour Function Description Pink RESET Reset Pink RESET Reset Green D0 WG output D0 White D1 WG output D1 Grey ALARM Alarm negati...

Page 4: ...card Read user card 1 Read user card 2 Read admin add card 9 1 2 Delete user via admin card Read admin delete card Read user card 1 Read user card 2 Read admin delete card 9 2 Enter into programming...

Page 5: ...nal alarm sound 9 7 Door open time setting 4 0 99 Note Range is 0 99 seconds 0s equates to 50Ms 9 8 Alarm time setting 5 0 3 Note Range is 0 3 minutes Factory default is 1 minute 9 9 Red light mode se...

Page 6: ...controller PN10 supports Wiegand output It can be connected to a controller which supports Wiegand 26 input as its slave reader 11 2 PN10 works as a controller connecting to a slave reader PN10 suppo...

Page 7: ...can be communicated so in this case the user capacity for one door can be 20 000 The setting of both devices must be the same If the master codes were different the user enrolled in the outdoor unit...

Page 8: ...te 11 4 Two devices interconnected with anti passback Two doors Install one device on door 1 under anti passback subsidiary mode Install one device on door 2 under anti passback host mode This functio...