page 4

 

 

Since

 

each

 

of

 

these

 

penstocks

 

is

 

designed

 

to

 

comply

 

with

 

the

 

operating

 

conditions

 

of

 

each

 

installation,

 

there

 

are

 

several

 

options

 

to

 

install

 

the

 

FL

 

penstock.

 

The

 

most

 

notable

 

are

 

the

 

two

 

most

 

common

 

options:

 

one

 

is

 

bolted

 

to

 

an

 

existing

 

flange

 

and

 

the

 

other

 

is

 

mounted

 

on

 

a

 

wall

 

and

 

secured

 

with

 

anchors.

 

Each

 

of

 

these

 

options

 

is

 

described

 

in

 

detail

 

below.

 

 

 

To

 

mount

 

the

 

penstock

 

bolted

 

to

 

a

 

flange

 

(fig.

 

5),

 

these

 

steps

 

should

 

be

 

followed:

 

 

Position

 

the

 

penstock

 

supported

 

on

 

the

 

flange

 

of

 

the

 

installation,

 

checking

 

that

 

the

 

boreholes

 

coincide

 

with

 

the

 

penstock

 

body

 

boreholes.

 

 

After

 

ensuring

 

that

 

the

 

borehole

 

coincides,

 

remove

 

the

 

penstock

 

from

 

the

 

flange.

 

 

Clean

 

the

 

face

 

of

 

the

 

flange

 

where

 

the

 

penstock

 

is

 

to

 

be

 

mounted.

 

 

Position

 

a

 

sealtight

 

joint

 

on

 

the

 

flange,

 

in

 

order

 

to

 

ensure

 

there

 

are

 

no

 

leakages

 

to

 

the

 

outside

 

where

 

the

 

flange

 

and

 

the

 

penstock

 

come

 

together.

 

The

 

seal

 

to

 

be

 

installed

 

will

 

be

 

selected

 

in

 

line

 

with

 

the

 

working

 

conditions

 

inside

 

the

 

line

 

(temperature,

 

pressure,

 

type

 

of

 

fluid,

 

etc).

 

 

Check

 

that

 

the

 

penstock,

 

the

 

inside

 

of

 

the

 

body

 

and,

 

above

 

all,

 

the

 

sealing

 

area

 

are

 

clean.

 

 

Clean

 

the

 

face

 

of

 

the

 

body

 

supported

 

on

 

the

 

flange.

 

 

Position

 

the

 

penstock

 

supported

 

on

 

the

 

flange.

 

 

Position

 

the

 

penstock

 

so

 

the

 

turning

 

point

 

of

 

the

 

flap

 

(body

 

lugs)

 

remains

 

in

 

the

 

upper

 

part

 

of

 

the

 

installation.

 

 

Ensure

 

that

 

the

 

sealtight

 

joint

 

between

 

the

 

flange

 

and

 

the

 

penstock

 

is

 

correctly

 

positioned.

 

 

After

 

correctly

 

positioning

 

both

 

the

 

sealtight

 

joint

 

and

 

the

 

penstock,

 

fasten

 

the

 

joining

 

bolts.

 

These

 

bolts

 

and

 

nuts

 

must

 

be

 

suitable

 

for

 

the

 

operating

 

conditions.

 

 

Once

 

all

 

the

 

bolts

 

are

 

in

 

place,

 

tighten

 

crosswise

 

with

 

a

 

low

 

initial

 

torque.

 

 

Finally,

 

complete

 

the

 

final

 

torque

 

in

 

accordance

 

with

 

the

 

applicable

 

standard.

 

 

After

 

carrying

 

out

 

all

 

these

 

steps

 

and

 

before

 

finishing

 

the

 

assembly

 

process,

 

check

 

that

 

the

 

flap

 

swivels

 

without

 

any

 

difficulty

 

on

 

the

 

turning

 

point.

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Installation

 

piping

 

fig.

 

5

 

Turning

 

point

 

Body

 

Flange

 

Sealtight

 

joint

 

Summary of Contents for FL Series

Page 1: ...gui Aldea 142 20400 Txarama Tolosa SPAIN MAN FL ES00 Tel National 902 40 80 50 Fax 902 40 80 51 Tel International 34 943 67 33 99 Fax 34 943 67 24 40 cmo cmo es http www cmo es page 1 17 09 2014 INSTR...

Page 2: ...d in the top part of the body using the holes fitted to secure the penstock and with the help of shackles If the equipment is packed in wooden boxes these must be provided with clearly marked holding...

Page 3: ...coincides with the penstock boreholes standard If the penstock is to be wall mounted inspect the wall to ensure it is clean and flat ASPECTS TO BE CONSIDERED DURING ASSEMBLY When mounting the penstoc...

Page 4: ...e flange in order to ensure there are no leakages to the outside where the flange and the penstock come together The seal to be installed will be selected in line with the working conditions inside th...

Page 5: ...paste such as SIKAFLEX 11FC or similar in order to prevent leakages between the body and the wall Return the penstock to its location above the sealing paste and introduce the chemical or expansion a...

Page 6: ...Once the equipment has been assembled make sure that there are no elements which can interfere with the flap movement The assembly of the equipment must be coordinated with the site s control and saf...

Page 7: ...de once the penstock is in place but before operating it If you are in an ATEX zone check the continuity between the different elements of the penstock EN 12266 2 annex B points B 2 2 2 and B 2 3 1 Ch...

Page 8: ...s will depend on the operating conditions of the penstock such as pressure temperature number of operations type of fluid and others These joints are bolted with flanges both the flanges and the bolts...

Page 9: ...that it is correctly fitted and the seal 3 has not been damaged in the process 9 Remove the systems to secure the flap 2 in open position and carefully position it in closed position 10 Before startin...

Page 10: ...ilation to prevent humidity The following aspects must be considered for storage purposes The storage place must be dry and under cover It is not recommended to store the equipment outdoors with direc...

Reviews: