background image

BA HHPC-170/21 60Hz englisch 

Art.Nr. 02505004/60/BECKER/ENG

Stand 05/2013

Seite 21 von 23

Summary of Contents for HHPC 170/21

Page 1: ...0 21 60Hz Translation C L BECKER GmbH Technischer Schiffs und Industriebedarf S derstra e 129 D 20357 Hamburg Tel 49 40 25 00 75 0 Fax 49 40 25 03 57 8 www clbecker de info clbecker de BA HHPC 170 21...

Page 2: ...lation Page 9 5 4 Storing of the device Page 9 6 Commissioning Page 10 6 1 Preparation for commissioning Page 10 6 2 First commissioning Page 11 12 6 3 Re Start Up Page 12 6 4 Operating with chemicals...

Page 3: ...00 Part 2 Chapter 2 36 this high pressure washer shall be subjected to an annual audit to guarantee safe operation The test results shall be recorded in writing C L Becker GmbH provides briefing train...

Page 4: ...ety informations which warn of rotating shafts This warning sign appears in this manual at all work safety informations which warn of hot surface This warning sign appears in this manual at all work s...

Page 5: ...describ Descript ssure nozzle al nozzle essure nozzle pipe pipe valve ssure hose motor prote on valve e gauge ssure water let al hose with s older technica es the comp tion e ction switch outlet suct...

Page 6: ...ched supplementary sheets Operation with chemicals optional Would you like to operate your high pressure washer using chemicals so attach the chemi stry hose with the suction filter in the fluid in th...

Page 7: ...tended and only as intended Always wear protective clothing 1 Protective helmet 2 Ear protection 3 Protective goggles 4 Face protection visor 5 Protective suit 6 Protective gloves 7 Protective boots T...

Page 8: ...care Observe safety rules and technical hazards and environmental regulations Please also note that the resulting effluent during the washing process can be made environmentally acceptable e g via an...

Page 9: ...on carefully and reject the installation site if there are safety concerns The device only has to be mounted vertically based on a horizontal flat surface and operated in such a position that it is ab...

Page 10: ...to become familiar with the function of its controls These are explained in the manual with reference to the relevant displays and illustrations Make sure that clean water flows to the device If the d...

Page 11: ...her Open the water supply Evacuate the air in high pressure pump high pressure hose and gun by the trigger lever pressing the gun without the nozzle until a uniform water jet emerges Then close the gu...

Page 12: ...he water filter insert It must be free from soiling Run the machine only with absolutely clean water Rinse the water hose before connecting with the machine Run the machine only vertically at a horizo...

Page 13: ...ach a short 3 4 hose attachment at the water inlet Place the other end of the hose into the container of antifreeze solution Turn the switch 0 1 2 to position 1 Press the black push button and open th...

Page 14: ...t our customer service at your disposal The following table lists the various maintenance intervals Activity Every day After 25 hours of work After 200 hours of work Once in the year As needed Sight c...

Page 15: ...L3 phase 3 PE protective conductor Q1 motor protection switch M motor 1 connection cable 2 motor connection cable Setting of motor protection switch 16A Fuse 16A tr ge gl BA HHPC 170 21 60Hz englisch...

Page 16: ...S33 High pres CLZ4150 High pres CLZS110 Seal kit h CLZVS1 mplete 00 rotating coup pling 101 pipe complete e without hig gh pressure n nozzle 60 double pipe v 360 valve ssure nozzle e 070E ssure hose 1...

Page 17: ...ting seal kit for 3 pistons 3x item no 42 44 45 47 56 CLVS3004 3 Spare part kit 3 consisting seal kit for 1 piston 1x item no 42 43 44 45 46 47 56 CLVS4002 1 Spare part kit 4 consisting oil seal kit s...

Page 18: ...er inlet C 60 Pump pistons 3 E Motor kW PS A 6 5 9 0 16 Degree of protection IP55 Power supply Volt Hz 3x460 60 Length mm 620 Width mm 520 Height mm 420 Weight kg 64 When using the recommended nozzles...

Page 19: ...the nameplate the pump is very noisy suction capacity insufficient or lower speeds than on the nameplate worn out valves cavity formation due to small suction pipes and or filters insufficient capaci...

Page 20: ...lectrical power before starting repair or maintenance Electricity can cause severe injuries Remove all references to faulty electrical equipment seriously and eliminate possible causes for accidents i...

Page 21: ...BA HHPC 170 21 60Hz englisch Art Nr 02505004 60 BECKER ENG Stand 05 2013 Seite 21 von 23...

Page 22: ...are attached to this manual 1 Warranty card If your high pressure cleaner has got additional equipment there are attached corresponding documents BA HHPC 170 21 60Hz englisch Art Nr 02505004 60 BECKE...

Page 23: ...Operator ______________________________ Location ______________________________ Date of test Hours of operation Test acc to BGR 500 part 2 chapter 2 36 Test acc to VDE 0701 0702 Test results Name of e...