Figure 3 & 4 - Installation SCT-20-H 

 

 

Installing the SCT-H 

 

  Follow all appropriate electrical codes and use only approved electrical 

fittings for the installation. 

 

  Choose a wall location that is free of obstructions and permits space for 

cable or conduit runs. 

SeeFigure 2 - 
Dimensions 

  Ensure mounting can support 4lbs (1.8kg) and any additional foreseeable 

load. 

 

  To avoid the possibility of creating sparks in a hazardous atmosphere 

disconnect the wiring at the demarcation block or ensure that the area is 
non-hazardous before proceeding. 

 

  To avoid shock hazard ensure that none of the electrical connection circuits 

are live by disconnecting the Tip and Ring conductors at the demarcation 
block. 

 

  Remove the eight (8) cover screws from the front of the unit and carefully 

remove the front cover assembly. NOTE that the handset and all 
electronics are attached to the front plate. The front cover may be 
separated from the back box by disconnecting the harness plugs. 

 

To change the Tone/Pulse setting to pulse, if required: 

Tip: The SCT-H is 
factory preset for DTMF 
tone. 

See: Figure 3 - 
Installation SCT-20-H 

Move the jumper from pins 1 & 2 of the Tone/Pulse connector to 
pins 2 & 3. 

To change the setting back to tone move the jumper back to pins 1 & 2. 

  Use the template provided to locate and drill holes for #8 or M4 mounting 

screws. 

  Attach the back box to the wall. If weather resistance is important in your 

application select washers that will assist in sealing the mounting holes. 

Tip: Use #8 or M4 
screws to secure the unit 
to the wall. 

Wiring the SCT-H to the Telephone System 

 

  Use the conduit hub provided or fit an appropriate cable gland, grommet or 

conduit connector to the 

7/8” opening in the bottom of the enclosure. 

 

  Bring cable into the enclosure through the opening and attach individual 

wires from the exchange (Tip/Ring/Ground) to the connector (Tip & Ring are 
not polarity sensitive).  If a conduit hub is used, ensure it is grounded to the 
ground stud. 

See: Figure 3 - Figure 
4 - Installation SCT-20-

  Ensure all connections are tight, then replace and secure the cover. 

 

  Connect the telephone into the system. 

 

  Test the unit by calling to and from another unit on the exchange. 

 

Summary of Contents for SCT-H Series

Page 1: ...erform repair and replacement If you are not a licensed elevator company or mechanic you are putting your life and those that ride elevators at risk Failure to have a qualified technician repair or in...

Page 2: ...tion in hazardous areas that are prone to high humidity chemical vapors dust and physical abuse Several variations and options are available to suit the end user s requirements Standard Features on Al...

Page 3: ...have a qualified technician repair or install elevator equipment will nullify any warranty and may cause death or injury PAGE 3 For a complete copy of our terms and conditions please call 708 867 4002...

Page 4: ...to perform repair and replacement If you are not a licensed elevator company or mechanic you are putting your life and those that ride elevators at risk Failure to have a qualified technician repair o...

Page 5: ...re live by disconnecting the Tip and Ring conductors at the demarcation block Remove the eight 8 cover screws from the front of the unit and carefully remove the front cover assembly NOTE that the han...

Page 6: ...nd separate from the housing by disconnecting the harness plugs NOTE that the handset and all electronics are attached to the front plate See Figure 3 Installation SCT 10 H SCT 30 H Figure 4 Installat...

Page 7: ...ess register can be assigned to each of the 10 number keys Each direct memory access register can contain up to 20 characters Tip Valid characters are 0 9 and Pause Lift the telephone handset off the...

Page 8: ...LING METHOD DTMF OR 40 60 PULSE AT 10 PPS TRANSMIT OBJECTIVE LOUDNESS RATING TOLR 38 3 dB RECEIVER VOLUME ADJUSTMENT 8 1 5 4 dB IN 5 STEPS OF 2 7 dB RECEIVE OBJECTIVE LOUDNESS RATING ROLR AT NOMINAL V...

Page 9: ...ns please call 708 867 4002 800 252 1910 or visit http www cjanderson com termsconditions aspx Rev A 3 18 Mechanical HOOK SWITCH CRADLE SWITCH LIFE 1 000 000 OPERATIONS BODY CONSTRUCTION 16 GA STEEL Z...

Page 10: ...ose used for eyeglasses or cameras may be used to clean the Telephone Premoistened towelettes may also be used however avoid those containing lanolin or aloe as they will leave a slippery residue The...

Reviews: