C.J. ANDERSON 636-701-SC-N7 User Manual And Quick Start Manual Download Page 5

IP Camera Network Setup Guide 

[email protected]

 

 

Phone: 800-252-1910 

Int: 708-867-4002 

www.cjanderson.com

 

of 

10 

 

 

 

DEFAULTS: Username: admin 

Password: 12345abc! 

 

 

Step 1. Install the SADP Software 

 

1. 

Download the SADP Tool from the website: 

https://www.cjanderson.com/hazardous-location-communication-devices/sadp-

download

 At the time this document was published, the file is named: 

SADPTool.zip 

and is 115 MB. 

2. 

Un-zip the file on a computer with Microsoft Windows (Windows 7 or newer) that is connected to the LAN where 
your camera is connected. 

3. 

Run the file contained in the zip file: 

SADPTool.exe

. Follow the on-screen instructions to install the file. 

NOTE : Be sure to allow the software administrative access or it will not work properly. 

4. 

Open the SADPTool application. When the application opens, it automatically 

“discovers” and lists all compatible 

devices on the LAN.  The discovery of devices can take several minutes. See below. 

 

 

 

Step 2. 

“Activate” Inactive Camera 

NOTE: Cameras are activated when shipped with the default IP Address of 192.168.3.xxx.  The last set of 
numbers in your IP address will be random, but will always be in the 192.168.3.xxx subnet. Network settings 
may be changed in the SADP Tool. See Step 3. Modify Network Parameters 

 

 

When a camera is first installed, or reset to its factory configuration, it must be 

“Activated” before it can be used. In the 

SADP Tool, “Inactive” devices have a 

Security 

status of 

Inactive

. A device is “Activated” when a password is 

assigned to the 

admin 

username of the device. 

In the example below, a camera is activated and configured for its network. 

Summary of Contents for 636-701-SC-N7

Page 1: ...IP Camera Network Setup Guide sales cjanderson com Phone 800 252 1910 Int 708 867 4002 www cjanderson com 1 of 10 USER MANUAL AND QUICK START GUIDE Network IP Cameras 636 701 SC N7...

Page 2: ...nings This installation should be made by a qualified service person and should conform to all the local codes Please install blackouts equipment into the power supply circuit for convenient supply in...

Page 3: ...etween 30 C 60 C and do not expose it to high electromagnetic radiation To avoid heat accumulation good ventilation is required for a proper operating environment Keep the camera away from water and a...

Page 4: ...not directly access any devices within the router firewall with a browser unless the device activated and setup with network parameters compatible with the router and the router is configured for port...

Page 5: ...tive access or it will not work properly 4 Open the SADPTool application When the application opens it automatically discovers and lists all compatible devices on the LAN The discovery of devices can...

Page 6: ...inistrator username a In the Device Activation window enter a password for admin in the New Password field Use a combination of uppercase lowercase alphabetic characters and numbers to create a Strong...

Page 7: ...at the bottom a Enable DHCP You can select Enable DHCP to acquire compatible network settings from a DHCP server installed on the LAN However these settings can be changed by the DHCP server Since it...

Page 8: ...xplorer to run as an Administrator Windows 7 To run Internet Explorer as an Administrator 1 Find or create an IE icon on your computer desktop 2 Hold down the shift key and then right click on the IE...

Page 9: ...L field In the example below the IP address of the camera is 192 168 3 100 2 In the login window enter admin for the User Name and password you created in the Password field then click Login 3 If this...

Page 10: ...ettings The reset button needs to be pressed with the camera disconnected from power Continue holding the reset button down and plug the camera back into power and continue to hold the reset button fo...