MAINTENANCE
After
Use
At the end of spraying, flush the system three times with fresh water. Finish with a final rinse using C-DAX
Neutralise
rinsing
solution.
Remove
the
strainer
basket
under
the
lid
of
the
sprayer,
rinse
and
refit.
Remove the main filter element, clean and replace, ensuring that the filter bowl ‘O’ ring is in place, and the bowl nut
is
tight.
Clean
the
outside
of
the
sprayer
to
remove
any
spray
residue.
Remove
and
rinse
the
nozzle
tip
filters.
Routinely
Check
the
spray
tip
patterns
for
wear,
replace
if
necessary.
Calibrate
the
boom
(every
100Ha)
Lubricate
any
moving
boom
parts.
Check
spray
hoses
for
kinks
or
damage,
replace
if
necessary.
Annually
Replace
spray
tips
Lubricate
the
break
away
joints
with
good
quality
grease.
Filters
Your
Pressure
nozzle
boom
sprayer
is
fitted
with
three
stage
filtration
consisting
of:
a)
filter
basket
at
the
tank
inlet,
b)
suction
filter
between
the
tank
and
pump,
and
c)
nozzle
tip
filters.
Check
all
filters
after
the
first
four
hours
of
use,
then
at
the
end
of
each
spraying
session,
more
regularly
depending
on
the
water
supply
and
chemicals
used.