EPS-300 

  1 

A. Important Notice

 

 

Before setting up and operating the instruments, please carefully read these instructions to 

get  familiarized  with  the  installation  and  operation  process.  Instructions  should  be  read  by 

experienced individuals before operating the instruments.     

Any  improper  usage  of  the  instruments  may  cause  damage.  Please  refer  to  the  safety 

notice included with this equipment. 

The instruments shall not be modified or altered in any way. Any modification or alteration 

will void the warranty, void the regulatory certifications and create potential safety hazard. C.B.S. 

Scientific is not responsible for any injury or damage caused by using the instruments for any 

non-intended purpose or injury as a result of modification of the instruments by any person who 

is not authorized by C.B.S. Scientific Company, Inc. 

 

A-1. Warranty 

 

EPS-300 is warranted to be free from defects in materials or workmanship for a period of 

one  year  from  the  original  invoice  date,  under  normal  usage.  Any  defects  occurring  during 

warranty period, C.B.S. Scientific will repair or replace defective products or parts without charge 

unless  the  defects  arise  from  conditions  outlined  below.  The  defects  described  below  are 

specially excluded from C.B.S. Scientific’s warranty policy.   

1.  Improper operation of the instrument. 

2.  Repair or modification by any person who is not authorized by C.B.S. Scientific 

3.  Damage caused by any (in)-direct accident, neglect or misuse. 

4.  Damage caused by disaster.   

5.  Damage caused by any improper solvents or samples 

 

A-2. Technical and Service Contact 

 

Most of the operation details are described in this instruction manual to assist and guide 

operator for an appropriate solution. For any other technical/ service questions, please contact 

your  local  representative  or  contact  C.B.S.  Scientific  technical  service  specialist  by  E-mail: 

[email protected]

 

 

Summary of Contents for EPS-300 II

Page 1: ...EPS 300 II and EPS 300 IIV Power Supply Installation and Operation Manual Version 1 0 This instrument is intended for laboratory use only...

Page 2: ...ct Description B 2 1 EPS 300 Power Supply Hardware Overview C Installation of EPS 300 Power Supply 5 C 1 Package List C 2 Setup and Operation of the EPS 300 Power Supply C 2 1 Unpacking C 2 2 Setup an...

Page 3: ...anty EPS 300 is warranted to be free from defects in materials or workmanship for a period of one year from the original invoice date under normal usage Any defects occurring during warranty period C...

Page 4: ...t the power supply using the AC power cord provided with the power supply or a similar 3 prong grounded AC outlet Use other than C B S Scientific s electrical cable with plugs or banana jacks is done...

Page 5: ...utput is controlled by setting a maximum value for voltage up to 300 V or current up to 500 mA The maximum output power at any time is 90 Watts The Run duration can be continuous or programmed to a ma...

Page 6: ...elected parameter 5 RUN Starts and Stops the output from the Power Supply The front and rear panel buttons as shown above are used to set up and run the EPS 300 power supply The audible alarm design a...

Page 7: ...ive Inspect all the components for damage that may have occurred while the unit was in transit If any part appears damaged contact the carrier immediately Be sure to keep all packing material for dama...

Page 8: ...un variable Press the MODE button to check and verify the set value of the other non constant run variable This variable is set by default to the maximum output of the power supply This is the normal...

Page 9: ...clock symbol Press the UP and DOWN buttons to enter in the run time in minutes Press both the UP and DOWN buttons at the same time The display will briefly show PF0 indicating that the PFD mode is dis...

Page 10: ...unction 4 Contact your local C B S Scientific representative Fan is spinning LED Display do not light up Front panel power on indicator off 1 Check main power source 2 Check if any errors on the front...

Page 11: ...etected at some point after a successful start Buffer is leaking from the cells There is a loose electrical connection in the circuit 1 Check and correct all potential resistance problems 2 Check buff...

Page 12: ...de Press any button except the RUN button to clear the error message D 3 Replacing the fuses 1 Unplug the power cord from the power supply 2 Locate the fuse compartment on the rear panel 3 Use a screw...

Page 13: ...pply and allow to dry completely Please contact your local representative or C B S Scientific technical service specialist by E mail technicalservice cbssci com C B S Scientific offers complete techni...

Page 14: ...z 5 200V 01 2A 200W max EPS 300 II Power Supply 120 V 50 60 Hz 10 300V 4 500mA 90W max EPS 300 IIV Power Supply 230 V 50 60 Hz 10 300V 4 500mA 90W max EPS 600 Power Supply 96 240 VAC 50 60 Hz 10 600V...

Page 15: ...C B S Scientific Company P O Box 856 Del Mar CA 92014 Phone 858 755 4959 email technicalservice cbssci com www cbsscientific com Printed in Taiwan...