7-X OPTIONS.
The 7 Options controls how the panel responds to given criteria. Some options
only apply if a communicator is fitted (Active 5X only) these are marked with a
⊗
.
OPTION 7-0. NIGHT SET OPTIONS.
70-1
Night set disable
70-2
Disable bells in Night set
70-3
⊗
Disable Communicator in Night set
70-4
Instant Set in Night set
OPTION 7-1. HOME SET OPTIONS.
71-1
Home set disable
71-2
Disable bells in Home set
71-3
⊗
Disable Communicator in Home set.
OPTION 7-2. ENGINEER OPTIONS.
72-1
Eng. only alarm reset. After a remote signalling alarm from the
ALARM trigger the system may only be reset by the installer or his
representative. Entry of the Engineer code is required befo re the
system will set again.
72-2
Eng. only PA reset. Following a PA alarm, which has been remotely
signalled the system must be reset by the installer or his
representative. Entry of the Engineer code is required before the
system will set again.
72-3
⊗
Silent P.A. alarm. If selected then any zone programmed as a P.A.
zone will send only a remote signal. The sounders and strobe light
will be suppressed.
72-4
⊗
45 Second communicator delay after alarm condition occurs
OPTION 7-3. LINE FAULT OPTIONS.
73-1
Convert keyswitch S1 & S+ to Line Fault
73-2
Disable Setting when a line fault is present.
73-3
Silent line fault
73-4
Suppress LED Display of line fault after 12 seconds.