Operation and Maintenance Instructions for

 

H2O-CPR-G

 

Spray Guns

Operation

1. Connect air supply hose at handle of gun.
2. Screw the paint cup onto the gun’s gravity feed fluid inlet.
3. Fluid flow can be controlled using the fluid control knob, this restricts flow by limiting needle travel. It is best to control

fluid flow by proper selection of fluid orifice size and use the fluid control knob to “fine tune flow rate”.

4. Fan width can be adjusted using the fan control knob. Turning the knob clockwise narrows the fan.

Maintenance

IMPORTANT! Routine cleaning and maintenance is essential to insure proper gun operation.
Several states prohibit spraying solvent into the atmosphere and require the use of covered gun cleaner.
1. If a gun cleaner is being used, connect and clean the gun in the gun cleaner according to the manufactures

instructions.

2. If a gun cleaner is not being used:

Remove air cap and clean separately using clean solvent.
Clean the gravity feed cup thoroughly, then spray clean solvent through the gun until clean.

NOTE: Gun head disassembly is not recommended for normal cleaning and maintenance.

Gun head disassembly and reassembly instructions:

Have repair kit # 10-105 available before gun disassembly.

Gun head disassembly

To remove the nozzle carrier (5) and air cap adapter (7):
1. Remove the air cap (1), fluid nozzle tip (2), fluid nozzle body (3), and needle (16).
2. Remove the needle seal cartridge (17).
3. Loosen the locknut (11) and remove fluid inlet (12) using a 11/16” open-end wrench.
4. The nozzle carrier (5) and air cap adapter (7) will now slide forward from the gun body (13).

Gun head reassembly

1. Install a new o-ring (4 & 8) on the air cap adapter (7).
2. Install the thread locknut (11) and seal (10) onto the fluid inlet (12) as far as possible.
3. Install a new fluid inlet seal (9) into the recess area on the nozzle carrier (5) inlet port.
4. Install carrier seal (6) onto the back of the nozzle carrier (5).
5. Slide the nozzle carrier (5) into air cap adapter (7) and insert into the gun body (13) as far as possible. Be sure the

nozzle carrier (5) extends into the hole at the back of the gun head. Install the needle seal (17) but do not tighten.

6. Rotate the nozzle carrier (5) until the fluid inlet port in the nozzle carrier (5) is aligned with the threaded hole in the

body. While in this position, insert the fluid inlet (12) and tighten firmly.

7. Tighten the needle seal (17) to approx. 12 ft.-lb. torque.
8. Tighten the fluid inlet (12) to approx. 25 ft.-lb. torque.
9. Tighten the locknut (11) to approx. 33 ft.-lb. torque.

Summary of Contents for H2O-CPR-G

Page 1: ...G Note Air cap test gages are available to confirm HVLP compliance H2O CPR G PPS Gun inlet pressures may vary as required by application 11 13 5 H2O CPR G 60 1504 S 23 2101 CPR Pressure Reduced 23 1301 HVLP 0 8 1 7 0 8 2 2 29 29 H2O CPR G GRAVITY FEED SPRAY GUN PRODUCT INFORMATION Coating Atomization Technologies 337 South Arthur Avenue Louisville CO 80027 Phone 888 820 4498 Fax 303 438 5708 www s...

Page 2: ...ssembly instructions Have repair kit 10 105 available before gun disassembly Gun head disassembly To remove the nozzle carrier 5 and air cap adapter 7 1 Remove the air cap 1 fluid nozzle tip 2 fluid nozzle body 3 and needle 16 2 Remove the needle seal cartridge 17 3 Loosen the locknut 11 and remove fluid inlet 12 using a 11 16 open end wrench 4 The nozzle carrier 5 and air cap adapter 7 will now s...

Page 3: ...l 28 60 202 Fluid Control Knob 11 60 118 Locknut 29 60 1510 Inlet Air Control Optional 12 60 127 Fluid Inlet 30 60 122 Plug 13 60 1119 CPR H2O CPR Gravity Gun Body 31 60 104 Air Inlet Fitting 14 98 0109 Allen Plug 51 401 Standard 700 mL Gravity Feed Cup Aluminum 15 See Air Cap Chart Fan Control Assembly 51 400 Optional 700 mL Gravity Feed Cup Plastic 16 See Air Cap Chart Fluid Needle 51 403 Option...

Page 4: ...01 11 CFM 23 1301 13 5 CFM 1 2 mm x 2101 or 1301 1 3 mm x 2101 or 1301 23 2101 13 23 1301 12 Revised 1 7 16 H2O CPR G PPS H2O CPR G EP H2O CPR G Includes 51 401 700 mL Aluminum Gravity Cup 98 0104 3 8 Socket 98 0112 Ratchet Wrench 60 8001 Gun Wrench 98 0113 Gun Cleaning Brush Air Caps and Needles Shown on Page 1 EP H2O CPR G PPS Includes 91 465 650 mL PPS Cup and Collar 91 466 Lids and Liners Avai...

Reviews: