4) Remote controller can not work
——
a,Remote control address is set to 1 (if the machine is set back to the factory defaults,remote control addresses need to be
back to 1 too)
b,Check whether the battery is installed on the remote controller or low .
c,Check the camera working mode is the normal operating mode
d,Check the menu whether is closed,camera control through remote controller is only available after exiting the menu.If video output
from LAN,menu will not be displayed,menu will automatically exists 30s later,then it can be controlled by remote controller.
5) Serial port can not work.
——
a,Check whether the camera serial device protocol,baud rate,address is consistent
b,Check whether the control cable is connected properly
c,Check whether the camera working mode is the normal operating mode
6) Web pages can not log in
——
a,Check whether the camera is showing normally.
b,Check whether the network cable is connected properly(Ethernet port yellow light flashes to indicate normal network cable
connection)
c,Check whether your computer is added the segment and the segment is consistent with the IP address of the camera
d,Click "Start" and select "Run" and then type “cmd” in the computer;Click "OK" then turn on a DOS command window to enter
ping 192.168.5.163. Press the Enter key to appear message as follows: Description network connection is normal