User Manual: Interactive Digital Signage
SW601990 Rev H, Page 24 of 36
Thermal Protection Mode icon will show on the top corner of these menus indicating that the
Thermal Protect Mode is active
The user will be prompted to shut off the monitor within sixty seconds if the temperature
continues to rise after Thermal Protection Mode Step 2 has been enabled. If the system is not
manually turned off in sixty seconds, the touchmonitor will automatically turn off to prevent
permanent damage to the monitor. The table below shows the Auto Shut Off temperature.
Note: This will only enable in extreme conditions.
Portrait and Landscape Mode
Monitor
Size
Thermal Protection
Mode (°C) Step 1
Thermal Protection
Mode (°C) Step 2
Auto Shut Off
Temperature (°C)
ET32/4201L 60
65
70
ET5501L 56
61
65
ET7001L 50
55
63
In the event that Thermal Protection Mode Step 1 or 2 has been enabled, the monitor will
resume full operational capabilities after the OSD temperature decreases to the values set forth
in the table below. These temperatures must be retained for at least five minutes.
Monitor
Size
Thermal Protection
Mode Step 1
Disabled (°C)
ET32/4201L
55
ET5501L 53
ET7001L 45