Important
1. Mounting any wire free object onto UPVC will reduce the operating range-as UPVC doors contain metal and act as a shield to the wire free signal.
2. Do not expose the Door Chime unit to rain or immerse in water.
3. Do not mount the either unit close to a fireplace or expose to high temperatures.
4. Do not drop the units or subject them to excessive blows.
5. The Converter and Door Chime units are designed for indoor use only.
6. Make sure no naked flame sources, such as lighted candles are placed on the unit.
7. The unit should not be exposed to dripping or splashing and no objects filled with liquids, such as vases should be placed on the unit.
8. Do not place near a PIR. It may interfere with your Door Chime.
9. Always use recommended batteries as these will give longer service and are less likely to leak.
10. Do not use different type of batteries, or mix up old and new batteries.
11. Do not leave exhausted batteries in either unit. If leaving the doorbell for long periods, remove the battery from the compartment to prevent
leakage.
12. Please dispose of old, defective batteries in an environmentally friendly manner in accordance with the relevant legislation.
13. CAUTION: Replace only with the same or equivalent type of battery that is recommended by the manufacturer.
14. CAUTION: Danger of explosion if battery is incorrectly installed or replaced.
Problem
Door Chime does not sound but LED
lights up on the Bell push.
Possible Causes
1. Units out of range (max. range 100m).
2. Bell push and Door Chime units are not on same
digital code.
Suggested Remedy
1. Operate the Door Chime unit within the
operation range (100m).
2. Re-set the digital code (see: Dip Switch
Settings).
Door Chime does not sound plus
no light on Bell push LED.
1. Flat bell push battery.
2. Wrong polarity of battery in Bell push.
1. Change the battery.
2. Re-insert battery as internal marking in right
polarity.
Door Chime sounds without Bell
Push being pressed.
A similar Wire Free Door Chime product is
operating nearby on the same frequency digital
code.
1. Re-set the digital code (see: Dip Switch
Settings).
Specification
Wirefree rechargeable chime kit
SX-201
100m
Operating
distance
Door chime unit
CR2032
100m
Wire Free
Batteries
Included
Batteries
Included
Operating
Distance
Loudness
Open Field
Open Field
80db
No wiring is required for this Wire Free portable Door Chime Kit. When the Bell Push is pressed, it sends a wire free signal to the Door Chime
unit that activates the chime. As the operating range is up to 100 meters (320ft. approx. – in open field), you can mount or take the Door
Chime virtually anywhere in the home. However, the transmission range of the wire free signal will be reduced if the signal is transmitted
through a number of walls or ceilings. Metal and UPVC doors and doorframes will also reduce the operating range.
Bell push unit
A
Bell Push Unit
2 x 3 volt Lithium batteries (CR2032) have already been installed.
Your Bell Push is ready to use.
Channel Selection – Dip Switch Settings
Before installing the Bell Push you should create your own combination of dip switch settings.
1. Remove the back of the Bell Push case by pushing in the tab on the bottom with a small, flat screwdriver
(dia.A).
2. Inside the Bell Push there is a 4 position dip switch marked 1, 2, 3 & 4. Use a screwdriver to alter the dip switch levers to either “ON” or
“OFF” positions, which can be altered to achieve a total of sixteen (16) possible digital codes.
3. Select any combination (e.g. 2 up 2 down)
(dia.B).
Do not refit the front cover of the Bell Push just yet.
Installation Guide
Important: Mounting the Bell Push unit on UPVC doors, doorframes or a metal surface will reduce the broadcasting range and may cause
intermitance.
Using the two holes on the back of Bell Push as a template (you will need to pierce the holes), mark the fixing position for the unit. If fixing into
a solid wall drill 6mm holes, fit wall plugs and secure the Bell Push unit with the 2 x 16mm screws provided. If fixing into timber, use a small
bradawl to make a pilot hole and fix directly with 2 x 16mm screws provided
(dia.C).
R
&
TTE
approved
C H Byron (Electrical) Ltd
www.chbyron.com
e-mail: [email protected]
U.K.
HELPLINE
0845-2301231
Bell push unit
Low battery
indicator
Flashing
light
Rechargeable
base
B
C
Type R2 Device - device where the
T
T
sound output is created by the
initial operation of the control and
where the period of sound output
continues for designed duration
irrespective of condition of the
control.
A. Push Button unit
Power
Consumption
: 2 x 3 volt Lithium battery (CR2032 - included)
r
: 7.0mA - ON
0.003mA - OFF
B. Door Chime unit
Power
Consumption
: 3 x 1.5 volt Ni-Mh batteries (included)
: 200mA - ON
0.3mA - Stand By
C. Charger Unit
Power
Operating Temperature
T
T
Operating Distance
Selectable Tone
T
T
Selectable Digital Code
: A/C-D/C 9 volt 300mA adaptor (Byron model SX-36 - included)
: -10
∞
0
0 C to +40
∞
0
0 C
: 100 metres (320 feet approx.) in open field
: Total eight (8) tones available
T
T
: Total sixteen (16) possible digital codes
T
T