do read this section carefully and observe all safety information at all times. 

2.2.1.

 

Battery module leakage 

If the battery modules leak electrolytes, contact with the leaking liquid or gas should be avoided. The 

electrolyte is corrosive, and the contact may cause skin irritation and chemical burns. If one is 

exposed to the leaked substance, do these actions: 

Inhalation: Evacuate the contaminated area and seek medical help immediately. 
Eye contact: Rinse eyes with flowing water for 15 minutes and seek medical help immediately. 

Skin contact: Wash the affected area thoroughly with soap and water and seek medical help 

immediately. 

Ingestion: Induce vomiting and seek medical help immediately. 

2.2.2.

 

Firefighting measures 

The battery modules may catch fire when it is put into the fire. In case of a fire, please make sure that 

an ABC or carbon dioxide extinguisher is nearby. Water cannot be used to extinguish the fire. 

Full protective clothing and self-contained breathing apparatus are required for the firefighters to 

extinguish the fire. 

2.2.3.

 

Battery modules handling and storage guide 

• The battery modules and its components should be protected from damage when transporting and

handling. 
• The weight of the system may cause injury risk. Please take the weight of the system into account

while the system is transported and lifted carefully. 
• Do not impact, pull, drag, or step on the battery modules.

• Do not insert unrelated objects into any part of the battery modules.
• Do not throw the battery module into a fire.

• Do not soak the battery modules in water or seawater.
• Do not expose to strong oxidizers.

• Do not short circuit the battery modules.
• The battery modules cannot be stored at high temperatures (more than 60 ℃).

• The battery modules cannot be stored directly under the sun.
• The battery modules cannot be stored in a high humidity environment.

• Use the battery modules only as directed.
• Do not use the battery modules if it is defective, or appears cracked, broken or otherwise damaged,

or fails to operate. 

• Do not attempt to open, disassemble, repair, tamper with, or modify the battery modules. The

battery modules are not user-serviceable. 

• Do not use cleaning solvents to clean the battery modules.

2.2.4.

 

  Warning of electric shock 

It is a danger to life due to electric shock when live components or DC cables are touched. 

Summary of Contents for HVL 12.0

Page 1: ...1 2 Be Connect 2 0 HVL 12 0 16 0 20 0 24 0 28 0 32 0 A High Voltage Battery System...

Page 2: ...2 ENGLISH 3 8 13 14 FRAN AIS Technical Parameters Instructions...

Page 3: ...nge without notice Every effort has been made to make this document complete accurate and up to date However BYD US may need to make some improvements under certain circumstances without advance notic...

Page 4: ...self The system could be connected with the Internet through network cable for maintenance and software updates The system must only be used as stationary equipment The system is suitable for indoor a...

Page 5: ...he fire 2 2 3 Battery modules handling and storage guide The battery modules and its components should be protected from damage when transporting and handling The weight of the system may cause injury...

Page 6: ...ith your local service partner During the storage of the battery system please mind the maximum storage time 2 2 6 Surge protection Overvoltages e g in the event of a flash of lightning can be further...

Page 7: ...e Beware of a danger zone This symbol indicates that the system must be additionally grounded if additional grounding or equipotential bonding is required at the installation site Keep the battery mod...

Page 8: ...exclusion ci dessus peut ne pas s appliquer Les sp cifications peuvent tre modifi es sans pr avis Tous les efforts ont t faits pour rendre ce document complet pr cis et jour Cependant BYD US peut avo...

Page 9: ...sur lui m me Le syst me peut tre connect Internet via un c ble r seau pour la maintenance et les mises jour logicielles Le syst me ne doit tre utilis que comme quipement fixe Le syst me convient une...

Page 10: ...l incendie 2 2 3 Guide de manipulation et de stockage des modules de batterie Les modules de batterie et composants doivent tre prot g s des dommages pendant le transport et la manipulation Le poids d...

Page 11: ...v rifi une fois par mois Si le syst me de batterie ne fonctionne pas normalement veuillez contacter votre partenaire de service local Pendant le stockage du syst me de batterie veuillez tenir compte d...

Page 12: ...flammes nues ou des sources d inflammation Attention au tension lectrique Attention au zone de danger Ce symbole indique que le syst me doit galement tre mis la terre si une mise la terre ou une liais...

Page 13: ...IEC60730...

Page 14: ...Hanger Wall Part M5 Screw Documents B A X1 BCU Base J X2 M4 Screw X1 X1 PE with Terminal terminal 5mm 10 cable mm 2 N O x2 x1 HVL Module J M4 Screw C M6 Rigid Conduit Hanger BCU Part Right I x1 3 4 co...

Page 15: ......

Page 16: ...Follow the UL 9045 2020 regarding the limitations for energy capacity and separation distances Notice...

Page 17: ...C D E H J 2Nm 8mm 5 5Nm mm 99 2Ib...

Page 18: ...7 8 9 11 12 1 2 G I 10 13 P 2 2Nm H P 2 H 2Nm 10mm 8Nm...

Page 19: ...INVERTER P P...

Page 20: ...ntion Bonding wire connected to this access panel internally Take care when removing the access panel 20 Connecting the Grounding Conductor and DC Cables Connexion du conducteur de mise la terre et de...

Page 21: ...4 3 2 O 21 5 1 K N...

Page 22: ...22 Double Insulated External Diameter 4 9mm Cross Section Area 6 16mm 2 For the right cable cross section please check the inverter manual as well 6 7 8mm 5 5Nm...

Page 23: ...1 2 23 9 HVL...

Page 24: ...4 3 1 2 1 2 3 4 5 6 7 8 A A Shield 1 2 2b B C D E Battery Box Battery Box SMA 4 3 1 2 B C D E Battery Box SMA Battery Box 24 SMA SBS 3 8 US 5 0 US 6 0 US Option a SMA SBS 3 8 US 5 0 US 6 0 US Option...

Page 25: ...2c 2d 1 2 3 4 5 6 7 8 H1 L1 1 2 GoodWe Shield 1 2 25 L1 H1 CAN1 H1 L1 1 2 GoodWe GoodWe Option a GoodWe Option b...

Page 26: ...NABLE GND BMS485B BMS485A RS485B RS485A MTR485B MTR485A Inner External A B CANL CANH ENABLE GND BMS485B BMS485A RS485B RS485A MTR485B MTR485A CANL CANH ENABLE GND BMS485B BMS485A RS485B RS485A MTR485B...

Page 27: ...2 3 10 1 27...

Page 28: ...2 2N H m If the panel is not closed the battery cannot be turned on NOTICE 28 Battery WLAN may be turned o in ve hours Press the LED button once around one second or restart the system to activate it...

Page 29: ...rivacy Policy DOWNLOAD FIRMWARE BYD 069D Battery Box Connect the Battery WiFi to Continue Password BYDB Box Check WIFI Settings Start 1 2 WLAN WLAN AVAILABLE NETWORKS BYD XXXX Connected no lnternet ac...

Page 30: ...ery Box Your batter system is succes ully con gured CONFIGURATION BYD 069D Battery Box TIME INVERTER SYSTEM GRID Next xxxxxx 6 CONFIGURATION BYD 069D Battery Box Next TIME INVERTER SYSTEM GRID Notice...

Page 31: ...31...

Page 32: ...14 1 OFF 2 5 seconds 3 SOC 30 SOC 30 32 Be Connect 2 0...

Page 33: ...15 33...

Page 34: ...BYD US Service 34 39 02 8738364 IT...

Page 35: ...35 35...

Page 36: ...35 35...

Reviews: